Powerex, Inc., 200 Hillis Street, Youngwood, Pennsylvania 15697-1800 (412) 925-7272
CR6CM
Lead-mount, Phase Control SCR
6 Amperes/400-600 Volts
Electrical and Thermal Characteristics, Tj = 25 °C unless otherwise specified
Characteristics
Symbol
Test Conditions
Voltage – Blocking State
Peak Forward Leakage
Peak Reverse Leakage
Current – Conducting State
IDRM
IRRM
Tj =125°C, VD = VDRM
Tj = 125°C, VR = VRRM
Peak On-state Voltage
DC Holding Current
Thermal Resistance
Junction-to-case
VTM
IH
Rth(j-c)
Tc = 25°C, ITM = 20A Peak
VD = 12V, Tj = 25°C
–
Gate– Parameters
Gate Current to Trigger
Gate Voltage to Trigger
Non-triggering Gate Voltage
IGT
VGT
VGD
VD = 6V, RL = 6⍀, Tj = 25°C
VD = 6V, RL = 6⍀, Tj = 25°C
VD = 1/2VDRM, Tj = 125°C
Min.
Typ. Max. Units
–
–
2
mA
–
–
2
mA
–
–
–
15
–
–
1.7 Volts
–
mA
3
°C/W
–
–
–
–
0.2
–
10
mA
1.0 Volts
–
Volts
P-41