1234567890123456789012345678901212345678901234567890123456789012123456789012L34O567W8901N23O45I67S8E90112162-3B456I7T890B12U34F56F78E90R12/3L45I6N789E01D212R34I5V67E89R012
Output Drive Characteristics (Over the Operating Range)
Parameters Description
IODL
Output LOW Current
IODH
Output HIGH Current
Test Conditions(1)
VCC = 5V, VIN = VIH OR VIL, VOUT = 1.5V(3)
VCC = 5V, VIN = VIH OR VIL, VOUT = 1.5V(3)
Min.
36
-100
Typ(2)
-166
Max.
-200
Units
mA
mA
Output Drive Characteristics (Over the Operating Range)
Parameters Description
Test Conditions(1)
VOH
Output HIGH Voltage VCC = Min., VIN = VIH or VIL IOH = –12.0 mA
VOL
Output LOW Voltage VCC = Min., VIN = VIH or VIL IOL = 12 mA
Min. Typ(2) Max. Units
2.4 3.3 — V
— 0.4 0.55 V
Capacitance (TA = 25°C, f = 1 MHz)
Parameters(4)
CIN
COUT
Description
Input Capacitance
Output Capacitance
Test Conditions
VIN = 0V
VOUT = 0V
Typ
Max.
Units
4.5
6
pF
5.5
8
pF
Notes:
1. For Max. or Min. conditions, use appropriate value specified under Electrical Characteristics for the applicable device type.
2. Typical values are at VCC = 5.0V, +25°C ambient and maximum loading.
3. Not more than one output should be tested at one time. Duration of the test should not exceed one second.
4. This parameter is determined by device characterization but is not production tested.
4
PS2049A 04/12/96