AC Characteristics (continued)
(VCC = 5.0V, VSS = 0V, TCI or TCM)
Parameter
Setup Time, WE Low before CAS Low (early-write operation only)
Hold Time, Column Address after CAS Low
Hold Time, Data 5
Hold Time, Row Address after RAS Low
Hold Time, WE High after CAS High 6
Hold Time, WE High after RAS High 6
1. All cycle times assume tT= 5ns, reference to VIH (min) and VIL (max).
2. To assume tPC min, tASC should be tCP.
3. In read-write cycle, tRWD and tRWL must be observed.
4. In read-write cycle, tCWD and tCWL must be observed.
5. Referenced to the later of xCAS or WE in write operations.
6. Either tRRH or tRCH must be satisfied for a read cycle.
Sym
tWCS
tCAH
tDH
tRAH
tRCH
tRRH
Min Max
0
-
15
-
15
-
10
-
0
-
0
-
Units
ns
ns
ns
ns
ns
ns
AC Characteristics
(VCC = 5.0V, VSS = 0V, TCI or TCM)
Parameter
Sym
Min Max
WE Low before CAS Low Hold Time (early-write operation only)
tWCH
15
-
OE Command Hold Time
tOEH
15
-
RAS Referenced to OE Hold Time
tROH
10
-
RAS from CAS Precharge (Fast Page Mode)
tRHCP 40
-
Column Address to WE Low Delay Time (read-write operation only)
tAWD 60
-
RAS Low to CAS High Delay Time (CBR refresh only)
tCHR
15
-
CAS High to RAS Low Delay Time (CAS to RAS Precharge Time)
tCRP
5
-
RAS Low to CAS High Delay Time (CAS Hold Time)
tCSH
70
-
CAS Low to RAS Low Delay Time (CAS Set-up Time)
tCSR
5
-
CAS Low to WE Low Delay Time (read-write operation only)
tCWD 45
-
OE to Data Delay Time
tOED
15
-
RAS Low to Column Address Delay Time 1
tRAD
15
35
Column Address to RAS High Delay Time
RAS Low to CAS Low Delay Time 1
tRAL
35
-
tRCD
20
50
RAS High to CAS Low Precharge Time
tRPC
5
-
CAS Low to RAS High Delay Time (RAS Hold Time)
tRSH
20
-
RAS Low to WE Low Delay Time (read-write operation only)
tRWD
95
-
WE Low after CAS Precharge Delay Time (read-write operation only)
tCWD 65
-
Refresh Time Interval
tREF
16
Transition time 2
tT
3
50
1. The maximum value is specified only to assure access time
2. Transition times (rise and fall) for RAS and xCAS are to be a minimum of 3ns and a maximum of 30ns.
Units
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ms
ns
Aeroflex Circuit Technology
4
SCD3750 REV A 8/31/98 Plainview NY (516) 694-6700