ISOLATION
In RS-485 applications, there are often long links, which can
cause the ground potential at different nodes on the bus to be
slightly different. This causes ground currents to flow through
the path of least resistance through either the common earth
ground or the ground wire. If the same electrical system is
used to connect the power supplies of all nodes to the same
earth ground, the ground connection may have reduced noise.
Note, however, that motors, switches, and other electrically
noisy equipment can still induce ground noise into the system.
When different nodes are situated in different buildings,
different power systems are required. This is likely to increase
the impedance of the earth ground and the ground currents
from other sources are more likely to find their way into the
link’s ground wire. Isolating the link reduces or even eliminates
these problems. Galvanic isolation is a perfect solution if there
is no guarantee that the potential at the earth grounds at
different nodes in the system are within the common-mode
range of the transceiver. Galvanic isolation allows information
flow, but prevents current flow (see Figure 13).
POINT A
ISOLATOR
POINT B
INFORMATION FLOW
NO GROUND CURRENT FLOW
ISOLATION
BARRIER
PROTECT HUMANS/
EQUIPMENT
ELIMINATE GROUNDING
PROBLEMS
IMPROVE SYSTEM
PERFORMANCE
Figure 13. Galvanic Isolation Allows Information Flow While Preventing
Ground Current Flow
The signal lines, as well as the power supply, must be isolated.
Power isolation is achieved by an isolated dc-dc supply, such as
Analog Devices, Inc. isoPower™, and signal isolation is achieved
via Analog Devices iCoupler® technology. See Figure 14 for an
example of how to achieve signal and power isolation using the
ADM2485.
LOCAL
POWER
SUPPLY
5V
100nF
VDD1
TxD
RTS
UART
RxD
5V CENTER TAPPED
TRANSFORMER
DA2303-AL RECTIFIER
1:11.5
VDD1
22µF
LDO
+5V ISO
IN
OUT
ADP3330
10µF
SD GND ERR
D1
D2
OSC
ENCODE
ENCODE
ADM2485
GND 2
DECODE
D
DECODE
100nF
VDD2
A
RT
B
DE OUT
RS-485 CABLE
DECODE
ENCODE
R
RE
GND1
DIGITAL ISOLATION iCoupler
RS-485 TRANSCEIVER
GND1
ISOLATION
BARRIER
GND2
Figure 14. Signal and Power Isolation using the ADM2485
Rev. 0 | Page 8 of 12