DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

ADUM5400(Rev0) Просмотр технического описания (PDF) - Analog Devices

Номер в каталоге
Компоненты Описание
производитель
ADUM5400 Datasheet PDF : 16 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
ABSOLUTE MAXIMUM RATINGS
TA = 25°C, unless otherwise noted.
Table 7.
Parameter
Storage Temperature (TST)
Ambient Operating Temperature (TA)
Supply Voltages (VDD1, VISO)1
VISO Supply Current2
−40°C to +85°C
−40°C to +105°C
Input Voltage (VIA, VIB, VIC, VID)1, 3
Output Voltage (VOA, VOB, VOC, VOD)1, 3
Average Output Current
per Data Output Pin4
Common-Mode Transients5
Rating
−55°C to +150°C
−40°C to +85°C
−0.5 V to +7.0 V
100 mA
60 mA
−0.5 V to VDDI + 0.5 V
−0.5 V to VISO + 0.5 V
−10 mA to +10 mA
−100 kV/μs to +100 kV/μs
1 Each voltage is relative to its respective ground.
2 VISO provides current for dc and dynamic loads on the Side 2 I/O channels.
This current must be included when determining the total VISO supply
current.
3 VDD1 and VISO refer to the supply voltages on the input and output sides of
a given channel, respectively. See the PCB Layout section.
4 See Figure 2 for maximum rated current values for various temperatures.
5 Refers to common-mode transients across the insulation barrier. Common-
mode transients exceeding the absolute maximum ratings may cause latch-up
or permanent damage.
ADuM5400
Stresses above those listed under Absolute Maximum Ratings
may cause permanent damage to the device. This is a stress
rating only; functional operation of the device at these or any
other conditions above those indicated in the operational
section of this specification is not implied. Exposure to absolute
maximum rating conditions for extended periods may affect
device reliability.
ESD CAUTION
Table 8. Maximum Continuous Working Voltage Supporting 50-Year Minimum Lifetime1
Parameter
Maximum Unit
Reference Standard
AC Voltage
Bipolar Waveform
424
V peak
50-year minimum lifetime
Unipolar Waveform
Basic Insulation
600
V peak
Maximum approved working voltage per IEC 60950-1
Reinforced Insulation
560
V peak
Maximum approved working voltage per IEC 60950-1 and VDE V 0884-10
DC Voltage
Basic Insulation
600
V peak
Maximum approved working voltage per IEC 60950-1
Reinforced Insulation
560
V peak
Maximum approved working voltage per IEC 60950-1 and VDE V 0884-10
1 Refers to the continuous voltage magnitude imposed across the isolation barrier. See the Insulation Lifetime section for more information.
Rev. 0 | Page 7 of 16