DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

A512ERW Просмотр технического описания (PDF) - MicroPower Direct, LLC

Номер в каталоге
Компоненты Описание
производитель
A512ERW Datasheet PDF : 2 Pages
1 2
Model Selection Guide
Input
Output
Model
Voltage (VDC)
Number
Nominal Range
Current (mA)
Full-Load No-Load
Reflected
Ripple
Current
(mA, Typ)
Voltage
(VDC)
Current
(mA, Max)
Current
(mA, Min)
A501ERW 12
9.0 - 18.0
429
20
25
3.3 1,200.0
60.0
A502ERW 12
9.0 - 18.0
514
20
25
5.0 1,000.0
50.0
A503ERW 12
9.0 - 18.0
595
20
25
12.0 500.0
25.0
A504ERW 12
9.0 - 18.0
595
20
25 ±12.0 ±250.0
±12.5
A505ERW 12
9.0 - 18.0
595
20
25 ±15.0 ±200.0
±10.0
A511ERW 24 18.0 - 36.0 209
5
15
3.3 1,200.0
60.0
A512ERW 24 18.0 - 36.0 251
5
15
5.0 1,000.0
50.0
A513ERW 24 18.0 - 36.0 291
5
15
12.0 500.0
25.0
A514ERW 24 18.0 - 36.0 291
5
15 ±12.0 ±250.0
±12.5
A515ERW 24 18.0 - 36.0 291
5
15 ±15.0 ±200.0
±10.0
Notes:
1. When measuring output ripple, it is recommended that an external 0.47 µF
ceramic capacitor be placed from the +Vout pin to the -Vout pin for single
output units and from each output to common for dual output units. For
noise sensitive applications, the use of 3.3 µF capacitors will reduce the
output ripple.
2. Transient recovery is measured to within a 1% error band for a load step
change of 75% to 100%.
3. Operation at no-load will not damage these units. However, they may not
meet all specifications.
4. Dual output units may be connected to provide a 10 VDC,
24 VDC or 30 VDC output. To do this, connect the load across the positive
(+Vout) and negative (-Vout) outputs and float the output common.
5. The converter should be connected to a low ac-impedance source. An
input source with a highly inductive impedance may affect the stability of
the converter. In applications where the converter output loading is high
and input power is supplied over long lines, it may be necessary to use a
capacitor on the input to insure start-up.
In this case, it is recommended that a low ESR (ESR <1.0Ω at 100 kHz)
capacitor be mounted close to the converter. For 12V input units a 3.3 µF
is recommended and for 24V units a 2.2 µF.
6. It is recommended that a fuse be used on the input of a power supply for
protection. See the table above for the correct rating.
Derating Curve
Mechanical Dimensions
Efficiency
(%, Typ)
77
81
84
84
84
79
83
86
86
86
Fuse Rating
Slow-Blow
(mA)
1,500
1,500
1,500
1,500
1,500
700
700
700
700
700
Pin Connections
Pin
Single
Dual
2
-Vin
-Vin
3
-Vin
-Vin
9
No Pin Common
11
NC
-Vout
14
+Vout +Vout
16
-Vout Common
22
+Vin
+Vin
23
+Vin
+Vin
NC: No Connection
Capacitive Load
Single Output Dual Output
µF Max
µF Max
6,800
±1,000
Mechanical Notes:
All dimensions are typical in inches (mm)
Tolerance x.xx = ±0.01 (±0.25)
MicroPower Direct
www.micropowerdirect.com
292 Page Street Ste D Stoughton, MA 02072 TEL: (781) 344-8226 FAX: (781) 344-8481 E-Mail: sales@micropowerdirect.com

Share Link: 