HI-200, HI-201
Application Information
Single Supply Operation
The switch operation of the HI-200/201 is dependent upon
an internally generated switching threshold voltage
optimized for ±15V power supplies. The HI-200/201 does not
provide the necessary internal switching threshold in a single
supply system. Therefore, if single supply operation is
required, the HI-300 series of switches is recommended.
The HI-300 series will remain operational to a minimum +5V
single supply.
Switch performance will degrade as power supply voltage is
reduced from optimum levels (±15V). So it is recommended
that a single supply design be thoroughly evaluated to
ensure that the switch will meet the requirements of the
application.
For further information see Application Notes AN520,
AN557, AN1033 and AN1034.