DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

MBC450-1T24G Просмотр технического описания (PDF) - Power-One Inc.

Номер в каталоге
Компоненты Описание
производитель
MBC450-1T24G
Power-One
Power-One Inc. Power-One
MBC450-1T24G Datasheet PDF : 7 Pages
1 2 3 4 5 6 7
DATA SHEET
Notes:
1. Peak current rating on V1 is 120% of max, lasting < 30 Sec with max of 10% duty cycle.
2. Ripple is peak to peak with 20MHz bandwidth and 10uF (Tantalum capacitor) in parallel with a 0.1uF ceramic capacitor
at rated line voltage and load ranges.
3. Combined output power of V1 plus fan supply and standby supply should not exceed max, power rating.
4. Standby output voltage tolerance including set point.
5. Fan supply output voltage tolerance including set point accuracy, line and load regulation is +/-30% and needs min. 1%
load on V1 output to be within regulation band. Ripple and noise is less than 10%.
6. Specifications are for nominal input voltage, 25°C unless otherwise stated.
7. Power supply is shipped with J3 housing, pins 9 and 10 shorted to enable V1, main output.
8. Derate output power linearly to 80% from 90 Vac to 80 Vac input.
9. For ordering Side Fan or Top Fan mounting option product add S or T suffix with the model name.
10. Specifications subject to change without notice.
11. Air flow over long edge (either direction) required for air flow rating. See mechanical drawing below.
12. Warranty 2 years.
General Specifications
PARAMETER
Hold Up Time
Power Factor
Efficiency (Full Load)
MTBF
Switching Frequency
Isolation Voltage
Weight
DESCRIPTION/CONDITION
120 VAC
230 VAC
120 VAC
230 VAC
120 VAC
230 VAC
>250 khrs
PFC converter: Variable, 45-160kHz typical
4242 VDC
2121 VDC
900g (1.98 lbs)
10 mSec
10 mSec
0.98
0.95
88% (24V, 48V, 30V), 86% (12V, 15V), 83% (5V) typical
90% (24V, 48V, 30V), 86% (12V, 15V), 83% (5V) typical
Bellcore TR-332
Resonant converter: Variable, 35-250 kHz, 90 kHz typical
Input to Output
Input to Earth
Environmental
PARAMETER
Operating Temperature
Storage Temperature
Relative Humidity
Altitude
CE Mark
Conducted Emissions:
Static Discharge
RF Field Susceptibility
Fast Transients/Bursts
Radiated Emissions
Surge Susceptibility
Harmonic Current
DESCRIPTION/CONDITION
-20 to 70 °C
-40 to 85 °C
95% RH, non-condensing
Operating 10,000 ft.
Complies with LVD Directive
EN55022-B, CISPR22-B, FCC PART15-B
EN61000-4-2
EN61000-4-3
EN61000-4-4
EN55022-B, CISPR22-B, FCC PART15-B
EN61000-4-5
EN61000-3-2
See derating charts below.
Non-operation 40,000 ft.
Level 3
Level 3
Level 3
To be controlled in end system
Level 3
Class D