DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

VRE3050 Просмотр технического описания (PDF) - Cirrus Logic

Номер в каталоге
Компоненты Описание
производитель
VRE3050
Cirrus-Logic
Cirrus Logic Cirrus-Logic
VRE3050 Datasheet PDF : 6 Pages
1 2 3 4 5 6
VRE3050
®
Product Innovation From
1. CHARACTERISTICS AND SPECIFICATIONS
ABSOLUTE MAXIMUM RATINGS
Power Supply............................ -0.3V to +40V
OUT, TRIM................................ -0.3V to +12V
NR............................................... -0.3V to +6V
Operating Temp. (A,B,C)............ 0ºC to +70ºC
Operating Temp. (J,K,L).......... -40ºC to +85ºC
ELECTRICAL SPECIFICATIONS
Out Short Circuit to GND Duration (VIN< 12V)............ Continuous
Out Short Circuit to GND Duration (VIN< 40V)......................5 sec
Out Short Circuit to IN Duration (VIN< 12V)................ Continuous
Continuous Power Dissipation (TA = +70ºC).................... 300mW
Storage Temperature......................................... -65ºC to +150ºC
Lead Temperature (soldering,10 sec).............................. +250ºC
VPS =+15V, T = +25ºC, RL = 10KΩ Unless Otherwise Noted.
Parameter
Symbol
Conditions
Min
Typ
Max
Units
Input Voltage
VIN
+8
+36
V
VRE3050A/J
+4.9995 +5.0000 +5.0005
Output Voltage (Note 1)
VOUT
VRE3050B/K
VRE3050C/L
+4.9992 +5.0000 +5.0008
V
+4.9990 +5.0000 +5.0010
Output Voltage
Temperature Coefficient
(Note 2)
TCVOUT
VRE3050A/J
VRE3050B/K
VRE3050C/L
0.3
0.6
0.5
1.0
ppm/ºC
1.0
2.0
Trim Adjustment Range
Turn-On Settling Time
Output Noise Voltage
Temperature Hysterisis
∆VOUT
TON
en
Figure 3
To 0.01% of final value
0.1Hz < f < 10Hz
10Hz < f < 1kHz
Note 4
±5.0
2.0
3.0
2.5
5.0
1
mV
µs
µVp-p
µVRMS
ppm
Long Term Stability
Supply Current
Load Regualtion (Note 3)
Line Regulation (Note 3)
∆VOUT/t
IIN
∆VOUT/ ∆IOUT
∆VOUT/ ∆VIN
Sourcing: 0mA ≤ IOUT ≤ 15mA
Sinking: -15mA ≤ IOUT ≤ 0mA
8V ≤ VIN ≤ 10V
10V ≤ VIN ≤ 18V
6
ppm/1000hrs.
3.5
4.0
mA
8
12
ppm/mA
8
12
25
35
ppm/V
5
10
NOTES:
1. The specified values are without external trim.
2. The temperature coefficient is determined by the box method. See discussion on temperature perfor-
mance.
3. Line and load regulation are measured with pulses and do not include voltage changes due to tem-
perature.
4. Hysterisis over the operating temperature range.