DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

VRE3025 Просмотр технического описания (PDF) - Cirrus Logic

Номер в каталоге
Компоненты Описание
производитель
VRE3025
Cirrus-Logic
Cirrus Logic Cirrus-Logic
VRE3025 Datasheet PDF : 7 Pages
1 2 3 4 5 6 7
VRE3025
Product Innova tionFrom
1. Characteristics and Specifications
ABSOLUTE MAXIMUM RATINGS
Power Supply............................ -0.3V to +40V
OUT, TRIM................................ -0.3V to +12V
NR............................................... -0.3V to +6V
Operating Temp. (A,B,C)............ 0ºC to +70ºC
Operating Temp. (J,L)............. -40ºC to +85ºC
Out Short Circuit to GND Duration (VIN< 12V)............ Continuous
Out Short Circuit to GND Duration (VIN< 40V)......................5 sec
Out Short Circuit to IN Duration (VIN< 12V)................ Continuous
Continuous Power Dissipation (TA = +70ºC).................... 300mW
Storage Temperature......................................... -65ºC to +150ºC
Lead Temperature (soldering,10 sec).............................. +250ºC
ELECTRICAL Specifications
Vps 15V, T = +25ºC, RL = 10KΩ Unless Otherwise Noted.
Parameter
Input Voltage
Output Voltage (Note 1)
Output Voltage
Temperature Coefficient
(Note 2)
Trim Adjustment Range
Turn-On Settling Time
Output Noise Voltage
Temperature Hysterisis
Symbol
VIN
VOUT
TCVOUT
∆VOUT
TON
en
Conditions
VRE3025A/J
VRE3025B
VRE3025C/L
VRE3025A/J
VRE3025B
VRE3025C/L
Figure 3
To 0.01% of final value
0.1Hz < f < 10Hz
10Hz < f < 1kHz
Note 4
Min
+8
+2.4998
+2.4996
+2.4995
Typ
+2.500
+2.500
+2.500
0.3
0.5
1.0
±2.5
2
1.5
1.5
1
Max
+36
+2.5003
+2.5004
+2.5005
0.6
1.0
2.0
3.0
Units
V
V
ppm/ºC
mV
µs
µVp-p
µVRMS
ppm
Long Term Stability
Supply Current
Load Regualtion
Line Regulation
∆VOUT/t
IIN
∆VOUT/ ∆IOUT
∆VOUT/ ∆VIN
Sourcing: 0mA ≤ IOUT ≤ 15mA
Sinking: -15mA ≤ IOUT ≤ 0mA
8V ≤ VIN ≤ 10V
10V ≤ VIN ≤ 18V
6
ppm/1000hrs.
3.5
4.0
mA
8
12
ppm/mA
8
12
25
35
ppm/V
5
10
NOTES:
1. The specified values are without external trim.
2. The temperature coefficient is determined by the box method. See discussion on temperature perfor-
mance.
3. Line and load regulation are measured with pulses and do not include voltage changes due to tem-
perature.
4. Hysterisis over the operating temperature range.
2
VRE3025DS

Share Link: 