DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

VN920PEP-E Просмотр технического описания (PDF) - STMicroelectronics

Номер в каталоге
Компоненты Описание
производитель
VN920PEP-E
ST-Microelectronics
STMicroelectronics ST-Microelectronics
VN920PEP-E Datasheet PDF : 18 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
VN920PEP-E
ELECTRICAL CHARACTERISTICS (continued)
Table 8. Current Sense (9VVCC16V) (See figure 5)
Symbol
Parameter
Test Conditions
K1
dK1/K1
IOUT/ISENSE
Current Sense Ratio Drift
IOUT=1A; VSENSE=0.5V;
Tj= -40°C...150°C
IOUT=1A; VSENSE=0.5V;
Tj= -40°C...+150°C
K2
IOUT/ISENSE
IOUT=10A; VSENSE=4V; Tj=-40°C
Tj=25°C...150°C
dK2/K2
K3
Current Sense Ratio Drift
IOUT/ISENSE
IOUT=10A; VSENSE=4V;
Tj=-40°C...+150°C
IOUT=30A; VSENSE=4V; Tj=-40°C
Tj=25°C...150°C
dK3/K3
Current Sense Ratio Drift IOUT=30A; VSENSE=4V;
Tj=-40°C...+150°C
ISENSEO
Analog Sense Leakage
Current
VCC=6...16V; IOUT=0A;VSENSE=0V;
Tj=-40°C...+150°C
VSENSE
VSENSEH
Max Analog Sense Output
Voltage
Sense Voltage in
Overtemperature
conditions
VCC=5.5V; IOUT=5A; RSENSE=10K
VCC>8V; IOUT=10A; RSENSE=10K
VCC=13V; RSENSE=3.9K
RVSENSEH
Analog sense output
impedance in
overtemperature
condition
VCC=13V; Tj>TTSD; Output Open
tDSENSE
Current sense delay
response
to 90% ISENSE (see note 2)
Note: 2. Current sense signal delay after positive input slope
Min
3300
Typ
4400
Max Unit
6000
-10
+10
%
4200
4400
4900
4900
6000
5750
-8
+8
%
4200
4400
4900
4900
5500
5250
-6
+6
%
0
10
µA
2
V
4
V
5.5
V
400
500
µs
Table 9. Protections (See note 3)
Symbol
Parameter
Test Conditions
Min. Typ. Max. Unit
TTSD
TR
Thyst
Shut-down Temperature
Reset Temperature
Thermal Hysteresis
150
175
200
°C
135
°C
7
15
°C
Ilim
DC Short Circuit Current
VCC=13V
5V<VCC<36V
30
45
75
A
75
A
Vdemag
Turn-off Output Clamp
Voltage
IOUT=2A; VIN=0V; L=6mH
VCC-41 VCC-48 VCC-55 V
VON
Output Voltage Drop
Limitation
IOUT=1A; Tj=-40°C....+150°C
50
mV
Note: 3. To ensure long term reliability under heavy overload or short circuit conditions, protection and related diagnostic signals must be
used together with a proper software strategy. If the device is subjected to abnormal conditions, this software must limit the duration
and number of activation cycles.
5/18

Share Link: 