µPG154TB
ABSOLUTE MAXIMUM RATINGS (TA = +25°C)
Parameter
Control Voltage 1, 2
Supply Voltage
Input Power
Total Power Dissipation
Operating Temperature
Storage Temperature
Symbol
VCONT1, 2
VDD
Pin
Ptot
TA
Tstg
Note Condition 2.5 ≤ | VCONT1 – VCONT2 | ≤ 6.0 V
Ratings
–6.0 to +6.0Note
5.0
+31
0.15
–45 to +85
–55 to +150
Unit
V
V
dBm
W
°C
°C
Remarks 1. Mounted on a 50 × 50 × 1.6 mm double copper clad epoxy glass PWB, TA = +85°C
2. Operation in excess of any one of these parameters may result in permanent damage.
PIN CONNECTIONS
Pin No.
1
2
3
Connection
OUT1
VDD
OUT2
Pin No.
4
5
6
Connection
VCONT2
IN
VCONT1
(Top View)
3
4
2
5
1
6
(Bottom View)
4
3
5
2
6
1
RECOMMENDED OPERATING CONDITIONS (TA = +25°C)
Parameter
Control Voltage (Low)
Control Voltage (High)
Supply Voltage
Symbol
VCONT
VCONT
VDD
MIN.
–0.2
+2.5
+2.5
TYP.
0
+3.0
VCONT(H)
MAX.
Unit
+0.2
V
+5.3
V
VCONT(H) + 0.3
V
2
Data Sheet P13656EJ2V0DS00