DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

UPD6461GS Просмотр технического описания (PDF) - NEC => Renesas Technology

Номер в каталоге
Компоненты Описание
производитель
UPD6461GS Datasheet PDF : 60 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
µPD6461, 6462
1.2 HOW TO SELECT MASK OPTIONS
To select mask options, use the option setting command (OC) of the Character Pattern Editor, a tool designed for editing
character pattern data.
Activate the Character Pattern Editor, then display the following setting menu:
OC (COMMAND INPUT)
OPTION DATA (0---LSB FAST , 1---MSB FAST ) :
OPTION DATA (0---V:9H
, 1---V:3H
):
OPTION DATA (0---RGB+3BLK , 1---RGB+VC1+VC2 ) :
OPTION DATA (0---OUTPUT 20 , 1---OUTPUT 21 ) :
OPTION DATA (0---OUTPUT 10 , 1---OUTPUT 11 ) :
OPTION DATA (0---EXT CLK , 1---LC
):
OPTION DATA (0---LC
, 1---EXT CLK ) :
......... (1)
......... (2)
......... (3)
......... (4)
......... (5)
......... (6)
......... (7)
Actually, the above menu is displayed one line at a time. Once you have selected an option, the next line is displayed.
Select 0 or 1 for lines (1), (2), (3), (6), and (7), according to the setting to be made. For the dot clock, however, make
the same settings (different values) for lines (6) and (7). For example, when selecting LC oscillation, select “LC” for both
lines (1 for (6) and 0 for (7)). Don’t select external clock input for lines (6) and/or (7).
When selecting the output distribution format, select the values on lines (4) and (5) as follows:
(4)
(5)
Option A 1(OUTPUT 21) 0(OUTPUT 10)
Option B 0(OUTPUT 20) 0(OUTPUT 10)
Option C 1(OUTPUT 21) 1(OUTPUT 11)
The settings are valid only when RGB+VC1+VC2 mode has been selected. Select option A (1, 0) when RGB+3BLK mode
has been selected.
The following table lists the correspondence between the command bits and the lines of the setting menu. Specify 0
or 1 for each bit.
D7 D6 D5 D4 D3 D2 D1 D0
0 (1) (2) (3) (4) (5) (6) (7)
Command OD displays the result of the selection, as a hexadecimal number.
Example: When the mask options are selected as follows:
Mask option
MSB first
Specification in three-line units
RGB+3BLK
Option A (only option A can be
specified in RGB+3BLK mode)
LC oscillation
Bit
Command
D6
1
D5
1
D4
0
D3
1
D2
0
D1
1
D0
0
The command bits are set as follows:
D7 D6 D5 D4 D3 D2 D1 D0
0
1
1
0
1
0
1
0
Command OD displays 6AH.
9