µPC2533
The reference voltage of the µPC2533-01 and µPC2533-02 detection comparator has been internally fixed at
1.0 V.
Under the influence of R501 (5 kΩ) and R502 (5 kΩ) of the siganl meter circuit (Fig. 2-6), signal meter output voltage
and detection comparator input voltage do not perfectly coincide. For SD sensitivity setting, refer to the following
formula.
Detection comparator input voltage =
Signal meter output voltage × (1 +
R501
)
Value of resistor between pin 7 and GND
Remark Because DC output is open-collector type (Active high), connect pull-up resistor to pin 10 to use.
18