DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

UEI25-120-D48PL1-C(2010) Просмотр технического описания (PDF) - Murata Manufacturing

Номер в каталоге
Компоненты Описание
производитель
UEI25-120-D48PL1-C
(Rev.:2010)
Murata
Murata Manufacturing Murata
UEI25-120-D48PL1-C Datasheet PDF : 11 Pages
1 2 3 4 5 6 7 8 9 10
UEI25-120 Series
Single Output Isolated 25-Watt DC/DC Converters
FUNCTIONAL SPECIFICATIONS (CONT.) – MODEL UEI25-120-D48
OUTPUT
Total Output Power
Voltage
Nominal Output Voltage
Setting Accuracy
Output Voltage Range
Overvoltage Protection
Current
Output Current Range
Minimum Load
Current Limit Inception
Short Circuit
Short Circuit Current
Short Circuit Duration (remove short for
recovery)
Short circuit protection method
Hiccup autorestart duty cycle
Regulation
Line Regulation
Load Regulation
Ripple and Noise
Temperature Coefficient
Maximum Capacitive Loading (10% ceramic,
90% Oscon)
MECHANICAL (Through Hole Models)
Outline Dimensions (no baseplate)
(Please refer to outline drawing)
Weight
Conditions
See Derating
No trim
At 50% load
User-adjustable
Via magnetic feedback
97% of Vnom., after warmup
Hiccup technique, autorecovery within ±1.25%
of Vout
Output shorted to ground, no damage
Current limiting
Output shorted to ground
Vin=min. to max., Vout=nom., 50% load
Iout=min. to max., Vin=48V
5 Hz- 20 MHz BW
At all outputs
Cap. ESR=<0.02Ω, full resistive load
Conditions ➀ ➂
C75 case
WxLxH
Through Hole Pin Diameter
Through Hole Pin Material
TH Pin Plating Metal and Thickness
ENVIRONMENTAL
Operating Ambient Temperature Range
Tref Location
Storage Temperature
Thermal Protection/Shutdown
Electromagnetic Interference
Conducted, EN55022/CISPR22
Radiated, EN55022/CISPR22
Relative humidity, non-condensing
Altitude
Nickel subplate
Gold overplate
With derating, 200 LFM
Measured in center
Vin = Zero (no power)
Measured at hotspot
External filter is required
To +85°C
must derate -1%/1000 feet
RoHS rating
Minimum
0.0
11.88
-1
-10
14
0.0
110
0
Minimum
-40
-55
130
10
-500
-152
Typical/Nominal
25.2
12.00
19
2.1
No minimum load
Continuous
TBD
95
0.02
Typical/Nominal
0.96x1.1x0.32
24.38x27.94x8.13
0.32
9.07
0.04
1.016
Copper alloy
TBD
TBD
135
B
B
RoHS-6
Maximum
25.45
12.12
+1
+10
22
2.1
130
0.1
Units
W
Vdc
% of Vset.
% of Vnom.
Vdc
A
% of IoutMax
A
±0.075
±0.05
120
470
Maximum
85
125
150
90
10,000
3048
%
% of Vout
% of Vout
mV pk-pk
% of Vnom./°C
μF
Units
Inches
mm
Ounces
Grams
Inches
mm
μ-inches
μ-inches
°C
°C
°C
Class
Class
%RH
feet
meters
Notes
Unless otherwise noted, all specifications are at nominal input voltage, nominal output
voltage and full load. General conditions are +25˚ Celsius ambient temperature, near
sea level altitude, natural convection airflow. All models are tested and specified with
external parallel 1 μF and 10 μF multi-layer ceramic output capacitors. The external
input capacitor is 4.7 μF ceramic. All capacitors are low-ESR types wired close to the
converter. These capacitors are necessary for our test equipment and may not be
needed in the user's application.
Input (back) ripple current is tested and specified over 5 Hz to 20 MHz bandwidth.
Input filtering is Cbus=220 μF, Cin=33 μF and Lbus=12 μH.
All models are stable and regulate to specification under no load.
The Remote On/Off Control is referred to -Vin.
Regulation specifications describe the output voltage changes as the line voltage or
load current is varied from its nominal or midpoint value to either extreme.
www.murata-ps.com
email: sales@murata-ps.com
17 Aug 2010 MDC_UEI25-120.A02 Page 5 of 11

Share Link: 