DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

5962-0324601Q9A Просмотр технического описания (PDF) - Atmel Corporation

Номер в каталоге
Компоненты Описание
производитель
5962-0324601Q9A Datasheet PDF : 42 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
TSC695FL
Synchronous Traps
Table 3. Synchronous Traps
Trap
Reset
Priority
1
Non-restartable, imprecise
error
2.1
Non-restartable,
precise error
2.2
Register file error
2 2.3
Restartable, late error
2.4
Restartable,
precise error
2.5
Instruction access
3
(Error on instruction fetch)
Illegal Instruction
4
Privileged instruction
5
FPU disabled
6
Overflow
Window
7
Underflow
Memory address not aligned
8
Non-restartable error
9.1
Data bus error
9.2
Restartable error
9.3
Sequence error
9.4
Unimplemented FPop
9.5
IEEE exceptions:
9 9.6
Trap Type (tt) Comments
Sources: SYSRESET* pin
-
software reset
watchdog reset
IU or System error reset
Severe error requiring a re-boot
64h
TSC695FL enters (if not masked) in halt or reset mode.
Error not removable, PC & nPC OK
62h
TSC695FL enters (if not masked) in halt or reset mode.
Special case of non-restartable, precise error.
65h
TSC695FL enters (if not masked) in halt or reset mode.
Retrying instruction but PC & nPC have to be re-adjusted
63h
TSC695FL enters (if not masked) in halt or reset mode.
Retrying instruction
61h
TSC695FL enters (if not masked) in halt or reset mode.
Parity error on control bus
Parity error on data bus
Parity error on address bus
Access to protected or unimplemented area
01h
Uncorrectable error in memory
Bus time out
Bus error
02h
-
03h
-
04h
-
05h
During SAVE instruction or trap taken
06h
During RESTORE instruction or RETT instruction
07h
-
Severe error, cannot restart the instruction.
Parity error on FPU data bus.
Can be removed restarting the instruction.
-
-
Invalid operation
08h
Division by zero
Overflow
Underflow
Inexact
9
4204C–AERO–05/05

Share Link: 

datasheetq.com  [ Privacy Policy ]Request Datasheet ] [ Contact Us ]