DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

ACA-20PC-4-AC3-GS Просмотр технического описания (PDF) - DATEL Data Acquisition products

Номер в каталоге
Компоненты Описание
производитель
ACA-20PC-4-AC3-GS
Datel
DATEL Data Acquisition products  Datel
ACA-20PC-4-AC3-GS Datasheet PDF : 5 Pages
1 2 3 4 5
ACA-20PC Series
3½ D I G I T , L E D D I S P L A Y , A C A M M E T E R S
Performance/Functional Specifications
Typical at TA = +25°C, unless otherwise noted. Œ
Rated Full-Scale Current 
Min. Typ. Max.
Units
ACA-20PC-1-XXX-XX
— 1.999
Amps
ACA-20PC-2-XXX-XX Ž
— 19.99
Amps
ACA-20PC-3-XXX-XX
— 50.0
Amps
ACA-20PC-4-XXX-XX
— 100.0
Amps
Overcurrent Rating 
1.5 x rated full-scale current
Performance
Sampling Rate
2.5 samples per second
Accuracy 
±0.15%FS ±6 counts
Measurement Type
Sine wave input, full-wave
averaging, rms calibrated
Temperature Drift (0 to +60°C)
— ±0.2 ±0.4
Counts/°C
Zero-Current Reading
–001 000 001
Counts
Dielectric Withstanding Voltage 2000 —
Vdc
Power Supply Voltage 
ACA-20PC-X-AC1-XX
85 120 264 Vac@47-99Hz
ACA-20PC-X-AC2-XX
85 120 140 Vac@350-450Hz
ACA-20PC-X-AC3-XX
240 264 310 Vac@47-99Hz
ACA-20PC-X-DC1-XX
+4.75 — +40
Vdc
ACA-20PC-X-DC2-XX
+36 — +75
Vdc
ACA-20PC-X-DC3-XX
+4.75 — +5.25
Vdc
Power Supply Current 
ACA-20PC-X-AC1,3-XX
30
50
mA@47-99Hz
ACA-20PC-X-AC2-XX
30
50 mA@350-450Hz
ACA-20PC-X-DC1,2-XX
— +8 +12
mAdc
ACA-20PC-X-DC3-XX
— +80 +120
mAdc
Power Supply Terminal Block
ACA-20PC-1-AC1-RL & ACA-20PC-2-AC1-RL
(2A and 20A ac-powered models with 4-position terminal blocks):
Wire Size & Type
12-20AWG (solid), 14-20AWG (stranded)
Insulation Strip Length
0.25 inches
Screw Tightening Torque
4.4 pound-inches (0.5Nm)
Maximum Rated Current
20A with 12AWG solid wire;
15A with 14AWG solid or stranded wire
Maximum Rated Voltage
630V (VDE 0110-V. Group 2);
250V (VDE 0110-V. Group 3)
ACA-20PC-X-XXX-XX
(All other ac/dc-powered models with 2-position terminal blocks):
Wire Size & Type
16-24AWG (solid or stranded)
Insulation Strip length
0.25 inches
Screw Tightening Torque
3.6 pound-inches (0.4Nm)
Maximum Rated Voltage
310Vac
Display
Display Type and Size
3½ digit LED, 0.37”/9.4mm digit height
Overrange Indication
"1_ _ _ "
Decimal Point
Fixed, model dependent
Physical/Environmental
Operating Temperature
0
— +60
°C
Storage Temperature
–40 — +75
°C
Humidity (non-condensing)
0
95
%
Case Material
Polycarbonate
Physical/Environmental
Dimensions
Weight:
ACA-20PC-1-XXX-XX
ACA-20PC-2-XXX-XX
ACA-20PC-3-XXX-XX
ACA-20PC-4-XXX-XX
1.38"W x 0.88"H Depth is model
dependent (see Mechanical Specifications)
1.1 ounces (31 grams)
1.1 ounces (31 grams)
1.3 ounces (37 grams)
1.5 ounces (43 grams)
ΠThe ACA-20PC-1-AC1-RL and ACA-20PC-2-AC1-RL have 4-position on-board terminal
blocks. All other models have 2-position terminal blocks.
 Specified full-scale currents are those passing through the built-in CT's primary (load) circuit,
over the frequency of 45-450Hz. The Overcurrent Rating is a continuous rating that applies to
the measured ac load current. It does not apply to any circuitry external to the meter.
Accuracy is guaranteed to the rated current.
 For the ACA-20PC-2-AC1-RL, if the load is connected to the meter's on-board 4-position
terminal block, the 20A full scale range requires 12AWG solid copper wire on all connections.
If 14AWG solid copper wire is used, the current should be limited to 15A. See Figure 3.
 All specified maximum power supply currents are steady-state values. AC-powered models
can draw higher surges at initial turn-on.
 Maximum reverse polarity protection on "DC1" models is –40Vdc, and –50Vdc on "DC2"
models. "DC3" models provide no reverse polarity protection.
Ordering Information
ACA - 20PC - 1 - AC1 - RL
Input Range:
1 = 1.999A
2 = 19.99A
3 = 50.0A
4 = 100.0A
LED Color:
RL = Red Standard
RH = High-Intensity Red*
GS = Green Standard*
Power Supply:
* Available on "DC3" +5V
powered models only
AC1 = 85-264Vac@50/60Hz
AC2 = 85-140Vac@400Hz
AC3 = 240-310Vac@50/60Hz
DC1 = +5-40Vdc
DC2 = +36-75Vdc
DC3 = +5Vdc
Accessories: DMS-20-CP Panel cutout punch
A DMS-BZL4 bezel assembly with sealing gasket is supplied with each ammeter.
Technical Notes
IMPORTANT! To ensure safe and reliable operation, ACA-
20PC ammeters must be installed and serviced by qualified
technical personnel. Contact DATEL if there is any doubt
regarding ammeter installation and/or operation.
1. Measurement Type: ACA-20PC ac ammeters employ a full-wave-
rectified, average responding, rms-calibrated circuit to measure the
stepped-down output of their on-board, L1 current transformer (CT) .
Stated accuracy specifications are measured using a sine-wave
current at or close to the specified full scale input level, at nominal line
frequency.
2. Calibration: Periodic recalibration of ACA-20PC ammeters is not
required under normal, indoor operating environments. If user
calibration is necessary, it should be performed by qualified technical
personnel. Calibration is performed with potentially lethal voltages
applied to the ACA-20PC and its associated wiring, with the specified
full-scale current flowing through the ammeter’s built-in current
transformer. A plastic, fully insulated adjusting tool must be used to
DATEL, Inc., Mansfield, MA 02048 (USA) Tel: (508)339-3000, (800)233-2765 Fax: (508)339-6356 E–mail: sales@datel.com Internet: www.datel.com
2

Share Link: 