Individual Electrical Characteristics (Ta = 25°C)
Characteristic
Forward voltage
Reverse current
Capacitance
Off-state current
Capacitance
Symbol
VF
IR
CT
IOFF
COFF
Test Condition
IF = 10 mA
VR = 5 V
V = 0, f = 1 MHz
VOFF = 350 V
V = 0,f = 1MHZ
TLP206G
Min. Typ. Max. Unit
1.0 1.15 1.3
V
—
—
10
µA
—
30
—
pF
—
—
1
µA
—
40
—
pF
Coupled Electrical Characteristics (Ta = 25°C)
Characteristic
Trigger LED current
On-state resistance
Symbol
IFT
RON
Test Condition
ION = 120 mA
ION = 120 mA, IF = 5 mA
MIn. Typ. Max. Unit
—
1
3
mA
—
22
35
Ω
Isolation Characteristics (Ta = 25°C)
Characteristic
Capacitance input to output
Isolation resistance
Isolation voltage
Symbol
CS
RS
BVS
Test Condition
VS = 0, f = 1 MHz
VS = 500 V, R.H. ≤ 60%
AC, 1 minute
AC, 1 second, in oil
DC, 1 minute, in oil
Min. Typ. Max. Unit
—
0.8
—
pF
5×1010 1014
—
Ω
1500 —
—
Vrms
— 3000 —
— 3000 —
Vdc
Switching Characteristics (Ta = 25°C)
Characteristic
Symbol
Test Condition
Min. Typ. Max. Unit
Turn-on time
Turn-off time
tON
tOFF
RL = 200Ω
(Note 3) —
0.3
VDD = 20 V, IF = 5 mA
—
0.1
1
1
ms
(Note 3): Switching time test circuit
IF 1, 3
2, 4
6, 8
RL
VDD
VOUT
5, 7
IF
VOUT
tON
10%
90%
tOFF
3
2002-09-25