CONSTANT VOLTAGE AND CONSTANT CURRENT CONTROLLER
FOR ADATPTORS AND BATTERY CHARGERS
TJ1051
ELECTRICAL CHARACTERISTICS
Tamb = 25and Vcc = +5V (unless otherwise specified)
Symbol
Parameter
Total Current Consumption
Total Supply Current - not taking the
Icc
output sinking current into account
Voltage Control Loop
Gmv
Transconduction Gain (Vctrl). Sink
Current Only 1)
Vref Voltage Control Loop Referenc 2)
Iibv Input Bias Current (Vctrl)
Current Control Loop
Gmi
Transconduction Gain (Ictrl). Sink
Current Only 3)
Vsense Current Control Loop Reference4)
Iibi Current out of pin Ictrl at - 200mV
Output Stage
Vol
Low output voltage at 10 mA sinking
Current
Ios Output Short Circuit Current. Output to
Vcc. Sink Current Only
Test Condition
Tamb
0 < Tamb < 85
Tamb
0 < Tamb < 85
Tamb
0 < Tamb < 85
Tamb
0 < Tamb < 85
Tamb
0 < Tamb < 85
Iout =2.5mA Tamb
0 < Tamb < 85
Tamb
0 < Tamb < 85
Tamb
0 < Tamb < 85
Tamb
0 < Tamb < 85
Min Typ Max Unit
1.1
2
mA
1.2
1
1.198
1.186
3.5
2.5
1.21
50
100
mA/mV
1.222
V
1.234
nA
1.5
7
mA/mV
196
204
200
mV
192
208
25
50
200
mV
27
50 mA
35
1) If the voltage on Vctrl (the negative input of the amplifier) is higher than the positive amplifier input (Vref=1.210V),
and it is increased by 1mV, the sinking current at the output OUT will be increased by 3.5mA.
2) The internal Voltage Reference is set at 1.210V (bandgap reference). The voltage control loop precision takes into
account the cumulative effects of the internal voltage reference deviation as well as the input offset voltage of the trans
conductance operational amplifier. The internal Voltage Reference is fixed by bandgap, and trimmed to 0.5% accuracy
room temperature.
3) When the positive input at Ictrl is lower than - 200mV, and the voltage is decreased by 1mV, the sinking current at the
output OUT will be increased by 7mA.
4) The internal current sense threshold is set to - 200mV. The current control loop precision takes into account
the cumulative effects of the internal voltage reference deviation as well as the input offset voltage of the trans-