DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

TES3-4813WI Просмотр технического описания (PDF) - Traco Power

Номер в каталоге
Компоненты Описание
производитель
TES3-4813WI
Traco
Traco Power Traco
TES3-4813WI Datasheet PDF : 3 Pages
1 2 3
DC/DC Converters
TES 3WI Series
3 Watt
Input Specifications
Input current (full load)
24 V models: 150 mA typ.
48 V models: 75 mA typ.
Input current (no load)
24 V models: 20 mA typ.
48 V models: 10 mA typ.
Start-up voltage / under voltage shut down
24 V models: 8.5 VDC / 8 VDC typ.
48 V models: 17 VDC / 16 VDC typ
Surge voltage (1 sec. max.)
24 V models: 50 V max.
48 V models: 100 V max.
Reverse voltage protection 1.0 A max.
Reflected input ripple current
24 V models: 10 mA typ.
48 V models: 5 mA typ.
Input filter EN 55022 class A, FCC part 15, level A
Output Specifications
Voltage set accuracy ±1 %
Regulation
– Input variation Vin min. to Vin max. 0.5 % max.
– Load variation 10 – 100 % single output models: 1.0 % max.
dual output models balanced load: 2.0 % max.
Minimum load 10 % of rated max current (operation at lower
load condition is safe but a higher output ripple
will be experienced)
Temperature coefficient ±0.02 %/°C max.
Ripple and noise 75 mVpk-pk max.
Dynamic load response (25% load change)
6 % max. peak variation
500 µS max. response time
Transient response (25% load step change) 200 µs typ.
Current limitation >120 % of Iout max.
Short circuit protection continuous, automatic recovery
Capacitive load
single output models: 3000 µF
dual output models: ±180 µF
Remote On/Off
– On: 2.5 to 5.5 V or open circuit
– Off: –0.7 to 0.8 V or short circuit pin 3 and pin 1/2
Off idle current: 5 mA
General Specifications
Temperature ranges
– Operating –40°C to +71°C
– Case temperature +100°C max.
– Storage –40°C to +125°C
Humidity (non condensing) 95 % rel H max.
Reliability, calculated MTTF (MIL-HDBK-217F, @+25°C, ground benign) >1‘000‘000 h
Isolation voltage (60 sec.) – Input/Output 1‘500 VDC
Isolation capacitance
– Input/Output 500 pF max.
Isolation resistance
– Input/Output >1‘000 Mohm
Switching frequency 300 kHz typ. (frequency modulation PFM)
Safety standards UL 60950-1, IEC/EN 60950-1
Safety approvals CSA File No. 226037
http://directories.csa-international.org
(entry pending)
All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated.
http://www.tracopower.com
Page 2 of 3