TB62709NG/FG
Operating modes (Table 1.)
These ICs support the following five operating modes :
1. Blank
: Forcibly turns OFF the constantcurrent output both for data and for digit setting. This
mode is not affected by the values in bits D11 to D0.
2. Normal Operate : Used for display operations after the settings of the digits are complete. Note that setting
this mode without making any other settings will cause display of the numeral 0.
3. Load Register
: Used for the detail settings of the Duty Control Register, for setting Decode / No Decode,
for inputting display data, and for setting the number of digits to drive. D11 to D0 of the
shift register are used for the detail settings of the digits currently being driven (Table 2).
4. All On
: Forcibly turns ON the dataside constantcurrent output. This mode is not affected by
D11 to D0.
The initial setting is four digits. When the digits must be changed,
use Load Register mode to set the number of digits to drive.
5. Standby
: Used to set Standby state (in which internal data are not cleared) and to clear data
(initialization). The settings in D3 to D0 of the shift register determine the choice between
standby state or initialization.
Table 1 Operating mode settings
D15
BLANK (OUTn &
DIG0~3 ALLOFF)
0
NORMAL (OPERATION)
0
LOAD REGISTER (DUTY,
DECODE, DIGIT & DATA)
0
ALL ON (OUTn ALLON)
0
STANDBY
0
REGISTER DATA
D14
D13
D12 D11~D8 D7~D4 D3~D0 HEX CODE
0
0
0
0−−−H
0
0
1
1−−−H
0
1
0
X
X
X
2XXXH
0
1
1
3−−−H
1
0
0
X
4−−XH
X = Input H or L. "" = Are not affected by the truth table.