Micrel, Inc.
TRUTH TABLE(1)
SY10E016
SY100E016
CE
PE
TCLD
MR
CLK
X
L
X
L
Z
L
H
L
L
Z
L
H
H
L
Z
H
H
X
L
Z
X
X
X
L
ZZ
X
X
X
H
Z
NOTE:
1. Z = Clock Pulse (LOW-to-HIGH), ZZ = Clock Pulse (HIGH-to-LOW)
Function
Load Parallel (Pn to Qn)
Continuous Count
Count; Load Parallel on TC = LOW
Hold
Master respond, Slaves Hold
Reset (Qn : = LOW, TC : = HIGH)
DC ELECTRICAL CHARACTERISTICS
VEE = VEE (Min.) to VEE (Max.); VCC = VCCO = GND
TA = –40°C
TA = 0°C
TA = +25°C
TA = +85°C
Symbol
Parameter
Min. Typ. Max. Min. Typ. Max. Min. Typ. Max. Min. Typ. Max. Unit
IIH
Input HIGH Current
— — 150 — — 150 — — 150 — — 150
µA
IEE
Power Supply Current
mA
10E — 151 181 — 151 181 — 151 181 — 151 181
100E — 151 181 — 151 181 — 151 181 — 174 208
AC ELECTRICAL CHARACTERISTICS
VEE = VEE (Min.) to VEE (Max.); VCC = VCCO = GND
TA = –40°C
TA = 0°C
TA = 25°C
TA = +85°C
Symbol
Parameter
Min. Typ. Max. Min. Typ. Max. Min. Typ. Max. Min. Typ. Max. Unit
fCOUNT Max. Count Frequency
700 900 — 700 900 — 700 900 — 700 900 — MHz
tPD
Propagation Delay to Output
ps
CLK to Q
600 725 1000 600 725 1000 600 725 1000 600 725 1000
MR to Q
600 775 1000 600 775 1000 600 775 1000 600 775 1000
CLK to TC (Qs loaded)(1)
550 775 1050 550 775 1050 550 775 1050 550 775 1050
CLK to TC (Qs unloaded)(1) 550 700 900 550 700 900 550 700 900 550 700 900
MR to TC
625 775 1000 625 775 1000 625 775 1000 625 775 1000
tS
Set-up Time
Pn
CE
PE
TCLD
ps
150 –30 — 150 –30 — 150 –30 — 150 –30 —
600 400 — 600 400 — 600 400 — 600 400 —
600 400 — 600 400 — 600 400 — 600 400 —
500 300 — 500 300 — 500 300 — 500 300 —
tH
Hold Time
Pn
CE
PE
TCLD
ps
250 30 — 250 30 — 250 30 — 250 30 —
0 –400 — 0 –400 — 0 –400 — 0 –400 —
0 –400 —
0 –400 —
0 –400 — 0 –400 —
100 –300 — 100 –300 — 100 –300 — 100 –300 —
tRR
Reset Recovery Time
900 700 — 900 700 — 900 700 — 900 700 —
ps
tWP
Minimum Pulse Width
CLK, MR
400 — — 400 — — 400 — — 400 — —
ps
tr
Rise/Fall Times
tf
20% to 80%
300 510 800 300 510 800 300 510 800 300 510 800
ps
NOTE:
1. CLK to TC propagation delay is dependent on the loading of the Q outputs. With all of the Q outputs loaded, the noise generated in going from a IIII IIII
state to a 0000 0000 state causes the CLk to TC+ delay to increase.
M9999-032006