IN74HC4052
MAXIMUM RATINGS*
Symbol
Parameter
Value
Unit
VCC Positive DC Supply Voltage (Referenced to GND)
-0.5 to +7.0
V
(Referenced to VEE)
-0.5 to +14.0
VEE Negative DC Supply Voltage (Referenced to GND)
-7.0 to +0.5
V
VIS Analog Input Voltage
VEE - 0.5 to VCC+0.5
V
VIN Digital Input Voltage (Referenced to GND)
-1.5 to VCC +1.5
V
I
DC Input Current Into or Out of Any Pin
±25
mA
PD
Power Dissipation in Still Air, Plastic DIP+
SOIC Package+
750
mW
500
Tstg Storage Temperature
-65 to +150
°C
TL
Lead Temperature, 1 mm from Case for 10 Seconds
260
°C
(Plastic DIP or SOIC Package)
*Maximum Ratings are those values beyond which damage to the device may occur.
Functional operation should be restricted to the Recommended Operating Conditions.
+Derating - Plastic DIP: - 10 mW/°C from 65° to 125°C
SOIC Package: : - 7 mW/°C from 65° to 125°C
RECOMMENDED OPERATING CONDITIONS
Symbol
Parameter
Min Max Unit
VCC
Positive Supply Voltage (Referenced to GND)
(Referenced to VEE)
VEE
Negative DC Supply Voltage (Referenced to GND)
VIS
Analog Input Voltage
VIN
Digital Input Voltage (Referenced to GND)
VIO*
Static or Dynamic Voltage Across Switch
TA
Operating Temperature, All Package Types
2.0 6.0
V
2.0 12.0
- 6.0 GND V
VEE
VCC
V
GND VCC
V
-
1.2
V
-55 +125 °C
tr, tf
Input Rise and Fall Time (Channel Select VCC =2.0 V
0
1000
ns
or Enable Inputs)
VCC =4.5 V
0
500
VCC =6.0 V
0
400
* For voltage drops across the switch greater than 1.2 V (switch on), excessive VCC current may be drawn;
i. e., the current out of the switch may contain both VCC and switch input components. The reliability of the
device will be unaffected unless the Maximum Ratings are exceeded.
This device contains protection circuitry to guard against damage due to high static voltages or electric
fields. However, precautions must be taken to avoid applications of any voltage higher than maximum rated
voltages to this high-impedance circuit. For proper operation, VIN and VOUT should be constrained to the range
indicated in the Recommended Operating Conditions..
Unused digital input pins must be tied to an appropriate logic voltage level (e.g., either GND or VCC).
Unused Analog I/O pins may be left open or terminated.
500