SM5007 series
Switching Characteristics
3 V operation: VDD = 2.7 to 3.3 V, VSS = 0 V, Ta = 20 to 80 °C unless otherwise noted.
Parameter
Symbol
Condition
Rating
Unit
min typ max
Output rise time
tr
Measurement cct 2, load cct 1, 0.1VDD to 0.9VDD, CL = 15 pF
Output fall time
tf
Measurement cct 2, load cct 1, 0.9VDD to 0.1VDD, CL = 15 pF
Output duty cycle1
Duty
Measurement cct 2, load cct 1, Ta = 25 °C ,
V DD = 3 V, CL = 15 pF
fO = 1 6 M H z
fO = 3 0 M H z
Output disable delay time tPLZ
Output enable delay time2
tP Z L
Measurement cct 6, load cct 1, Ta = 25 °C , V D D = 3 V, CL 15 p F
Maximum operating
frequency
fmax Measurement cct 2, load cct 1, CL 15 p F
5
15
ns
5
15
ns
45
55
%
40
60
100 ns
100 ns
30
– MHz
Minimum operating
frequency
fmin Measurement cct 2, load cct 1, CL 15 p F
4 MHz
1. Determined by the lot monitor.
2. Oscillator stop function is built-in. When INH goes LOW , normal output stops. When INH goes HIGH, normal output is not resumed until after the
oscillator start-up time has elapsed.
5 V operation: VDD = 4.5 to 5.5 V, VSS = 0 V, Ta = 20 to 80 °C unless otherwise noted.
Parameter
Symbol
Condition
Rating
Unit
min typ max
Output rise time
tr
Measurement cct 2, load cct 1, 0.1VDD to 0.9VDD, CL = 15 pF
Output fall time
Output duty cycle1
tf
Measurement cct 2, load cct 1, 0.9VDD to 0.1VDD, CL = 15 pF
Duty Measurement cct 2, load cct 1, Ta = 25 °C , V D D = 5 V, CL = 15 p F
Output disable delay time tPLZ
Output enable delay time2
tP Z L
Measurement cct 6, load cct 1, Ta = 25 °C , V D D = 5 V, CL 15 p F
Maximum operating
frequency
fmax Measurement cct 2, load cct 1, CL 15 p F
3
9
ns
3
9
ns
45
55
%
100 ns
100 ns
30
– MHz
Minimum operating
frequency
fmin Measurement cct 2, load cct 1, CL 15 p F
4 MHz
1. Determined by the lot monitor.
2. Oscillator stop function is built-in. When INH goes LOW , normal output stops. When INH goes HIGH, normal output is not resumed until after the
oscillator start-up time has elapsed.
Current consumption and Output waveform with NPC’s standard crystal
Cb
L Ca R
f (MHz)
30
R ()
17.2
L (mH)
4.36
Ca (fF)
6.46
Cb (pF)
2.26
NIPPON PRECISION CIRCUITS—7