Si306x
Table 3. DC Characteristics, VD = 3.3 V
(VD = 3.0 to 3.6 V, TA = 0 to 70 °C)
Parameter
Symbol
Test Condition
Min
Typ
Max
Unit
Input Leakage Current
IL
Power Supply Current, Analog*
ID
VA pin
–10
—
—
9
10
µA
12
mA
*Note: This current is required from the integrated system-side interface to communicate with the Si306x through the
proprietary isolation interface.
6