General Purpose Relay – LY
Contact Rating
Relay
Single Contact
1-pole
2-, 3- or 4-pole
Load
Resistive load
(cosϕ = 1)
Inductive load
(cosϕ = 0.4,
L/R = 7 ms)
Resistive load
(cosϕ = 1)
Inductive load
(cosϕ = 0.4,
L/R = 7 ms)
Rated Load
110 VAC 15 A
24 VDC 15 A
110 VAC 10 A
24 VDC 7 A
110 VAC 10 A
24 VDC 10 A
110 VAC 7.5 A
24 VDC 5 A
Rated Carry
Current
15 A
10 A
Max. switching 250 VAC
voltage
125 VDC
250 VAC
125 VDC
Max. switching 15 A
current
10 A
Max. switching 1,700 VA
power
360 W
1,100 VA
170 W
1,100 VA
240 W
825 VA
120 W
Failure rate
100 mA, 5 VDC
(reference value)*
100 mA, 5 VDC
*Note: P level: λ60 = 0.1 x 10-6/operation
Bifurcated contacts
2-pole
Resistive load
(cosϕ = 1)
Inductive load
(cosϕ = 0.4,
L/R = 7 ms)
110 VAC 5A
24 VDC 5 A
110 VAC 4 A
24 VDC 4A
7A
250 VAC
125 VDC
7A
550 VA
120 W
100 mA, 5 VDC
440 VA
100 W
Characteristics
Item
All except Relays with bifurcated contacts
Relays with bifurcated contacts
Contact resistance
50 mmax.
Operate time
25 ms max.
Release time
25 ms max.
Max. operating frequency
Mechanical: 18,000 operations/hr
Electrical: 1,800 operations/hr (under rated load)
Insulation resistance
100 Mmin. (at 500 VDC)
Dielectric strength
1,000 VAC, 50/60 Hz for 1 min between contacts of same polarity
2,000 VAC, 50/60 Hz for 1 min between contacts of different polarity
Vibration resistance
Destruction: 10 to 55 to 10 Hz, 0.5 mm single amplitude (1.0 mm double amplitude)
Malfunction: 10 to 55 to 10 Hz, 0.5 mm single amplitude (1.0 mm double amplitude)
Shock resistance
Destruction: 1,000 m/s2
Malfunction: 200 m/s2
Endurance
Mechanical: AC: 50,000,000 operations min. (at 18,000 operations/hr)
DC: 1,00,000,000 operations min. (at 18,000 operations/hr)
Electrical: Single-, three-, and four-pole: 200,000 operations min.
(at 1,800 operations/hr under rated load)
Double-pole: 500,000 operations min. (at 1,800 operations/hr under rated load)
Ambient temperature*
Operating:
Single- and double-pole standard, bifurcated-contact Relays: –25°C to 55°C (with no icing)
(–25°C to 70°C if carry current is 4 A or less)
All other Relays: –25°C to 40°C (with no icing)
(–25°C to 55°C if carry current is 4 A or less)
Ambient humidity
Operating: 5% to 85%
Weight
Single- and double-pole: approx. 40 g, three-pole: approx. 50 g, four-pole: approx. 70 g
Note: 1. The values given above are initial values
2. The upper limit of 40°C for some Relays is because of the relationship between diode junction temperature and the element
used.