Philips Semiconductors
USB 2-port hub
Product specification
PDIUSBH12
ENDPOINT DESCRIPTIONS
There are two endpoint configuration modes supported by the PDIUSBH12, the Single Embedded Function mode and the Multiple (3)
Embedded Function mode. The Single Embedded Function mode is the default at power up reset. The Multiple (3) Embedded Function mode
can be configured by writing a zero to bit 7 of the first byte of the Set Mode command. Either mode is backward compatible to the PDIUSBH11.
Table 1. SINGLE EMBEDDED FUNCTION MODE (DEFAULT AT POWER UP)
FUNCTION
PORTS
ENDPOINT #
ENDPOINT
INDEX
TRANSFER
TYPE
Hub
0: Upstream
0
2–3: Downstream
1
0
1
Embedded
Function 1
1
2
3
NOTE:
1. Hub interrupt endpoint is not indexed.
2. Generic endpoint can be used for Interrupt or Bulk endpoint.
0
1
Control
Interrupt
2
3
Control
5
4
Generic
6
7
Generic
8
9
Generic
DIRECTION
OUT
IN
IN
OUT
IN
OUT
IN
OUT
IN
OUT
IN
MAX
PACKET SIZE
(BYTES)
8
8
1
8
8
8
8
8
8
8
8
Table 2. MULTIPLE (3) EMBEDDED FUNCTION MODE
FUNCTION
PORTS
ENDPOINT #
ENDPOINT
INDEX
Hub
Embedded
Function 1
Embedded
Function 6
Embedded
Function 7
0: Upstream
2–3: Downstream
1
6
7
0
0
1
1
2
0
3
5
1
4
10
0
11
6
1
7
12
0
13
8
1
9
TRANSFER
TYPE
Control
Interrupt
Control
Generic
Control
Generic
Control
Generic
DIRECTION
OUT
IN
IN
OUT
IN
OUT
IN
OUT
IN
OUT
IN
OUT
IN
OUT
IN
MAX
PACKET SIZE
(BYTES)
8
8
1
8
8
8
8
8
8
8
8
8
8
8
8
1999 Jul 22