DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

NCV7381 Просмотр технического описания (PDF) - ON Semiconductor

Номер в каталоге
Компоненты Описание
производитель
NCV7381
ON-Semiconductor
ON Semiconductor ON-Semiconductor
NCV7381 Datasheet PDF : 24 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
NCV7381
Internal Flags
The NCV7381 control logic uses a number of internal flags (i.e. onebit memories) reflecting important conditions or events.
Table 3 summarizes the individual flags and the conditions that lead to a set or reset of the flags.
Table 3. INTERNAL FLAGS
Flag
Set Condition
Local
Wakeup
Low level detected on WAKE pin in a low
power mode
Remote
Wakeup
Remote wakeup detected on the bus in a
lowpower mode
Wakeup
Local Wakeup flag changes to set
or
Remote Wakeup flag changes to set
Poweron
Thermal
Warning
Internal power supply of the chip becomes
sufficient for the operation of the control logic
Junction temperature is higher than Tjw
(typ. 140°C) in a normalpower mode
and
VBAT is not in undervoltage
Thermal
Shutdown
Junction temperature is higher than Tjsd
(typ. 165°C) in a normalpower mode
and
VBAT is not in undervoltage
TxEN
Timeout
Bus Error
TxEN is Low for longer than dBDTxAct-
iveMax (typ. 1.5 ms) and bus driver is in
Normal mode
Transmitter is enabled
and
Data on bus are different from TxD signal
(sampled after each TXD edge)
VBAT UnderVBAT is below the undervoltage threshold
voltage
for longer than dBDUVVBAT
VCC UnderVCC is below the undervoltage threshold for
voltage
longer than dBDUVVCC
VIO Under
voltage
VIO is below the undervoltage threshold for
longer than dUVIO
Error
Any of the following status bits is set:
Bus error
Thermal Warning
Thermal Shutdown
TxEN Timeout
VBAT Undervoltage
VCC Undervoltage
VIO Undervoltage
Reset Condition
Lowpower mode is entered
Lowpower mode is entered
Normal mode is entered
or
Lowpower mode is entered
or
Any undervoltage flag becomes set
Normal mode is entered
(Junction temperature is below Tjw in
a normalpower mode
or
the status register is read in a lowpower
mode)
and
VBAT is not in undervoltage
Junction temperature is below Tjsd in
a normalpower mode
and
falling edge on TxEN
and
VBAT is not in undervoltage
TxEN is High or Normal mode is left
(Transmitter is enabled
and
Data on bus are identical to TxD signal)
or
Transmitter is disabled
VBAT is above the undervoltage threshold
for longer than dBDRVBAT
or
Wake flag becomes set
VCC is above the undervoltage threshold
for longer than dBDRVCC
or
Wake flag becomes set
VIO is above the undervoltage threshold for
longer than dBDRVIO
or
Wake flag becomes set
All of the following status bits are reset:
Bus error
Thermal Warning
Thermal Shutdown
TxEN Timeout
VBAT Undervoltage
VCC Undervoltage
VIO Undervoltage
Comment
The thermal warning
flag has no influence
on the bus driver
function
The transmitter is
disabled as long as
the thermal shut-
down flag is set
The transmitter is
disabled as long as
the timeout flag is set
The bus error flag
has no influence on
the bus driver func-
tion
www.onsemi.com
6

Share Link: 

datasheetq.com  [ Privacy Policy ]Request Datasheet ] [ Contact Us ]