NCP1253
APPLICATION INFORMATION
Introduction
The NCP1253 implements a standard current mode
architecture where the switchoff event is dictated by the
peak current setpoint. This component represents the ideal
candidate where low partcount and cost effectiveness are
the key parameters, particularly in lowcost acdc adapters,
openframe power supplies etc. Capitalizing on the
NCP1200 series success, the NCP1253 brings all the
necessary components normally needed in today modern
power supply designs, bringing several enhancements such
as a VCC OVP or an adjustable slope compensation signal.
Currentmode operation with internal ramp
compensation: implementing peak current mode control
at a fixed 65 kHz or 100 kHz frequency, the NCP1253
offers an internal ramp compensation signal that can
easily by summed up to the sensed current. Sub harmonic
oscillations can thus be compensated via the inclusion of
a simple resistor in series with the currentsense
information.
Low startup current: reaching a low noload standby
power always represents a difficult exercise when the
controller draws a significant amount of current during
startup. Thanks to its proprietary architecture, the
NCP1253 is guaranteed to draw less than 15 mA
maximum, easing the design of low standby power
adapters.
EMI jittering: an internal lowfrequency modulation
signal varies the pace at which the oscillator frequency is
modulated. This helps spreading out energy in conducted
noise analysis. To improve the EMI signature at low
power levels, the jittering will not be disabled in
frequency foldback mode (light load conditions).
Frequency foldback capability: a continuous flow of
pulses is not compatible with noload/lightload standby
power requirements. To excel in this domain, the
controller observes the feedback pin and when it reaches
a level of 1.5 V, the oscillator then starts to reduce its
switching frequency as the feedback level continues to
decrease. When the feedback pin reaches 1.05 V, the peak
current setpoint is internally frozen and the frequency
continues to decrease. It can go down to 26 kHz (typical)
reached for a feedback level of 350 mV roughly. At this
point, if the power continues to drop, the controller enters
classical skipcycle mode.
Internal softstart: a softstart precludes the main power
switch from being stressed upon startup. In this
controller, the softstart is internally fixed to 4 ms.
Softstart is activated when a new startup sequence
occurs or during an autorecovery hiccup.
Latched OVP on Vcc: it is sometimes interesting to
implement a circuit protection by sensing the VCC level.
This is what NCP1253 does by monitoring its VCC pin.
When the voltage on this pin exceeds 25.5 V typical, the
pulses are immediately stopped and the part latches off.
When the user cycles the VCC down or the converter
recovers from a brownout event, the circuit is reset and
the part enters a new startup sequence.
Shortcircuit protection: shortcircuit and especially
overload protections are difficult to implement when a
strong leakage inductance between auxiliary and power
windings affects the transformer (the aux winding level
does not properly collapse in presence of an output short).
Here, every time the internal 0.8 V maximum peak
current limit is activated, an error flag is asserted and a
time period starts, thanks to an internal timer. When the
fault is validated, all pulses are stopped and the controller
enters an autorecovery burst mode, with a softstart
sequence at the beginning of each cycle. As soon as the
fault disappears, the SMPS resumes operation. Please
note that some version offers an autorecovery mode as
we just described, some do not and latch off in case of a
short circuit.
Startup Sequence
The NCP1253 startup voltage is made purposely high to
permit large energy storage in a small VCC capacitor value.
This helps to operate with a small startup current which,
together with a small Vcc capacitor, will not hamper the
startup time. To further reduce the standby power, the
startup current of the controller is extremely low, below
15 mA. The startup resistor can therefore be connected to
the bulk capacitor or directly to the mains input voltage if
you wish to save a few more mW.
http://onsemi.com