NB100LVEP221
Table 7. LVNECL DC CHARACTERISTICS VCC = 0 V, VEE = −2.375 V to −3.8 V (Note 10)
−40°C
25°C
85°C
Symbol
Characteristic
Min Typ Max Min Typ Max Min Typ Max Unit
IEE
VOH
VOL
VIH
VIL
VBB
VIHCMR
Power Supply Current
Output HIGH Voltage (Note 11)
Output LOW Voltage (Note 11)
Input HIGH Voltage (Single−Ended)
Input LOW Voltage (Single−Ended)
Output Reference Voltage (Note 12)
Input HIGH Voltage Common Mode
Range (Differential Configuration)
(Note 13)
CLK0/CLK0
CLK1/CLK1
100 125 150 104 130 156 116 145 174 mA
−1145 −1020 −895 −1145 −1020 −895 −1145 −1020 −895 mV
−1945 −1820 −1600 −1945 −1820 −1600 −1945 −1820 −1600 mV
−1165
−880 −1165
−880 −1165
−880 mV
−1945
−1600 −1945
−1600 −1945
−1600 mV
−1525 −1425 −1325 −1525 −1425 −1325 −1525 −1425 −1325 mV
VEE + 1.2
VEE + 0.3
0.0
−0.9
VEE + 1.2
VEE + 0.3
0.0
−0.9
VEE + 1.2
VEE + 0.3
0.0 V
−0.9 V
IIH
Input HIGH Current
IIL
Input LOW Current
CLK 0.5
CLK −150
150
0.5
−150
150
0.5
−150
150 mA
mA
NOTE: Device will meet the specifications after thermal equilibrium has been established when mounted in a test socket or printed circuit
board with maintained transverse airflow greater than 500 lfpm. Electrical parameters are guaranteed only over the declared
operating temperature range. Functional operation of the device exceeding these conditions is not implied. Device specification limit
values are applied individually under normal operating conditions and not valid simultaneously.
10. Input and output parameters vary 1:1 with VCC.
11. All outputs loaded with 50 W to VCC−2.0 V.
12. Single−ended input operation is limited VEE ≤ −3.0V in NECL mode.
13. VIHCMR min varies 1:1 with VEE, VIHCMR max varies 1:1 with VCC. The VIHCMR range is referenced to the most positive side of the differential
input signal.
Table 8. HSTL DC CHARACTERISTICS VCC = 3.3 V; VEE = 0 V
0°C
25°C
85°C
Symbol
Characteristic
Min Typ Max
Min Typ Max
Min Typ Max Unit
VIH
Input HIGH Voltage
CLK1/CLK1 Vx+100
VIL
Input LOW Voltage
CLK1/CLK1 −300
VX
Differential Configuration Cross
680
Point Voltage
1600 Vx+100
Vx−100
900
−300
680
1600 Vx+100
Vx−100
900
−300
680
1600 mV
Vx−100 mV
900 mV
IIH
Input HIGH Current
IIL
Input LOW Current
CLK1
CLK1
−150
−150
−250
150 −150
−150
−250
150 −150
−150
−250
150 mA
mA
NOTE: Device will meet the specifications after thermal equilibrium has been established when mounted in a test socket or printed circuit
board with maintained transverse airflow greater than 500 lfpm. Electrical parameters are guaranteed only over the declared
operating temperature range. Functional operation of the device exceeding these conditions is not implied. Device specification limit
values are applied individually under normal operating conditions and not valid simultaneously.
http://onsemi.com