MT9076B
Data Sheet
4.3 Identification Code
The MT9076 shall be identified by the code 01111000, read from the identification code status register (page
03H, address 1FH).
4.3.1 ST-BUS Streams
In T1 mode, there is one control and one status ST-BUS stream that can be used to program / access channel
associated signaling nibbles. CSTo contains the received channel associated signaling bits, and for those channels
whose Per Time Slot Control word bit 1 “RPSIG” is set low, CSTi is used to control the transmit channel associated
signaling. The DSTi and DSTo streams contain the transmit and receive voice and digital data. Only 24 of the 32
ST-BUS channels are used for each of DSTi, DSTo, CSTi and CSTo. In each case individual channel mapping is as
illustrated in Table 6, “ST-BUS vs. DS1 to Channel Relationship(T1),” on page 30.
In E1 mode, ST-BUS streams can also be used to access channel associated signaling nibbles. CSTo contains the
received channel associated signaling bits (e.g., ITU-T R1 and R2 signaling), and for those channels whose Per
Time Slot Control word bit 1 “RPSIG” is set low, CSTi is used to control the transmit channel associated signaling.
The DSTi and DSTo streams contain the transmit and receive voice and digital data.
Only 30 of the 32 ST-BUS channels are used for each of DSTi, DSTo, CSTi and CSTo. In each case individual
channel mapping is as illustrated in Table 10 Time slot to Channel Relationship.
5.0 Reset Operation (Initialization)
The MT9076 can be reset using the hardware RESET pin (pin 11 in PLCC, pin 64 in LQFP) or the software reset bit
RST (page 1H, address 1AH). When the device emerges from its reset state it will begin to function with the default
settings described in Table 14 (T1) Table 15 (E1). All control registers are set to 00H. A reset operation takes 1 full
frame (125 us) to complete.
Function
Mode
Loopbacks
SLC-96
Zero Coding
Line Codes
Data Link
signaling
AB/ABCD Bit Debounce
Interrupts
Error Insertion
HDLCs
Counters
Transmit Data
Table 14 - Reset Status(T1)
Status
D4
Deactivated
Deactivated
Deactivated
Deactivated
Serial Mode
CAS Registers
Deactivated
masked
Deactivated
Deactivated
Cleared
All Ones
37
Zarlink Semiconductor Inc.