DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

MT9079 Просмотр технического описания (PDF) - Mitel Networks

Номер в каталоге
Компоненты Описание
производитель
MT9079 Datasheet PDF : 54 Pages
First Prev 11 12 13 14 15 16 17 18 19 20 Next Last
MT9079
the interrupt vector is read it is automatically cleared
and IRQ will return to a high impedance state. In
ST-BUS mode, as well as processor and controller
modes, this function is accomplished by toggling the
INTA bit (page 1, address 1AH.)
All the interrupts of the MT9079 are maskable. This is
accomplished through interrupt mask words zero to
four, which are located on page 1, addresses 1BH to
1EH.
After a MT9079 reset (RESET pin or RST control bit)
all interrupts of mask words one, two and three are
masked; and the interrupts of mask word zero are
unmasked.
Interrupt Mask Word Zero
Bit 7
Bit 0
SYNI RAII AISI AIS16I LOSI FERI BPVO SLPI
Interrupt Mask Word One
Bit 7
Bit 0
EBI CRCI CEFI BPVI RCRI BERI --- SIGI
Interrupt Mask Word Two
Bit 7
Bit 0
EBO CRCO CALNI FERO RCRO BERO AUXPI ---
Interrupt Mask Word Three
Bit 7
Bit 0
MFSYI CSYNI RFALI YI 1SEC STOP STRT DATA
All interrupts may be suspended, without changing
the interrupt mask words, by making the SPND
control bit of page 1, address 1AH high.
Control and Status Registers
Address
(A4A3A2A1A0)
10H (Table 25)
11H (Table 26)
12H (Table 27)
13H (Table 28)
14H (Table 29)
15H (Table 30)
16H (Table 31)
17H (Table 32)
18H (Table 33)
19H (Table 34)
1AH (Table 35)
1BH (Table 36)
1CH (Table 37)
1DH (Table 38)
1EH (Table 39)
1FH
Register
Function
Multiframe, National Bit Buffer and Data ASEL, MFSEL, NBTB & Sa4 - Sa8
Link Selection
Mode Selection
TIU0, CRCM, RST, ARAI, AUTY, MODE,
CSYN & AUTC
Transmit Non-frame Alignment Signal
TIU1, TALM & TNU4-8
Transmit Multiframe Alignment Signal
TMA1-4, X1, Y, X2 & X3
ST-BUS Offset
SOFF7 - SOFF0
Coding and Loopback Control Word
COD1-0, HDB3, MFRF, DLBK, RLBK, SLBK &
PLBK
Transmit Alarm Control
TAIS, TAIS0, TAIS16, TE, REFRM, 8KSEL,
CIWA & CDWA
Code Insert Word
CIW7 - CIW0
Code Detect Word
CDW7 - CDW0
Code Detect Bit Mask
DWM7 - DWM0
Interrupt, Signalling and BERT Control
Word
RDLY, SPND, INTA,TxCAS, RPSIG & BFAS
Interrupt Mask Word Zero
SYNI, RAII, AISI, AIS16I, LOSI, FERI, BPVO
& SLPI
Interrupt Mask Word One
EBI, CRCI, CEFI, BPVI, RCRI, BERI & SIGI
Interrupt Mask Word Two
EBO, CRCO, CALNI, FERO, RCRO, BERO &
AUXPI
Interrupt Mask Word Three
MFSYI, CSYNI, RFALI, YI, 1SEC, STOP,
STRT & DATA
Unused.
---
Table 8 - Master Control Words (Page 1)
4-256