DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

MPB150 Просмотр технического описания (PDF) - Power-One Inc.

Номер в каталоге
Компоненты Описание
производитель
MPB150
Power-One
Power-One Inc. Power-One
MPB150 Datasheet PDF : 4 Pages
1 2 3 4
MPB150 Dual-Output AC-DC Series Data Sheet
Safety, Regulatory, and EMI Specifications
PARAMETER
CONDITIONS/DESCRIPTION
MIN
NOM
MAX
UNITS
Agency Approvals
UL60950-1.
CSA No. 60950-1.
EN60950-1.
IEC60950-1.
Dielectric Withstand Voltage
AC to chassis.
Input to output.
1500
VAC
3000
VDC
Electromagnetic Interference EN55022 Conducted.
Class A
6
dB
ESD Susceptibility
Per EN61000-4-2, Level 4
8
kV
Flicker
Per EN61000-3-3.
Radiated Susceptibility
Per EN61000-4-3.
3
V/m
EFT/Burst
Per EN61000-4-4.
1
kV
Input Transient Protection
Per EN61000-4-5, Level 3, 2 kV (Line-to-Gnd) minimum, 1 kV (Line-to-Line) minimum.
RF Immunity
Per EN61000-4-6. 0.15 to 80 MHz (1 kHz sinewave)
3
V/m
Magnetic Fields
Per EN61000-4-8.
1
A/m
Voltage Dips
Per EN61000-4-11.
Insulation Resistance
Input to output.
10
M
Leakage Current
Per EN60950 (264 VAC)
1.0
mA
Environmental Specifications
PARAMETER
Altitude
Operating Temperature
Storage Temperature
Forced-Air Cooling
Temperature Coefficient
Relative Humidity
Shock
Vibration
CONDITIONS/DESCRIPTION
MIN
NOM
MAX
UNITS
Operating
Non-Operating
10K ASL Feet
50K
Derate linearly from 50 to 70°C to 50% power at 70°C.
At 100% load: 0
MPB150 models will operate at -20°C, but will not meet all specifications.
50
°C
-40
85
°C
Forced-air cooling of 15 CFM is required for full output power. Air velocity
is measured with power supply mounted on 0.375" (9.5mm) standoffs.
Airflow direction is from the input section to the output section.
See Application Note for details.
Included in total regulation of outputs.
Non-Condensing.
5
85
%RH
Operating: 11 ±3ms, 3 axes, Half Sine.
Non-operating: 11 ±3ms, 3 axes, Half Sine.
15
Gpk
40
Operating: Random vibration, 5-500 Hz, 10 minutes each axis.
Non-Operating: Random vibration, 5-500 Hz, 10 minutes each axis.
2.4
GRMS
6.0
GRMS
MCD10078 Rev. 1.0, 28-Aug-08
Page 3 of 4
www.power-one.com

Share Link: 