MPB150 Dual-Output AC-DC Series Data Sheet
Features
• RoHS compliant for all six substances
• High power density in an industry-standard 3" x 5"
footprint
• Power Factor Correction (PFC) meets EN61000-3-2
• Main output remote sense
• Power Good signals
• CE marked to Low Voltage Directive
• Input transient & ESD compliance to
EN61000-4-2/-3/-4/-5
Description
The MPB150 Series incorporates patented high efficiency circuitry, high power density and active Power Factor
Correction (PFC) to meet the requirements of networking and data communications systems, as well as commercial
and industrial configurations.
MPB150’s deliver a regulated main output plus a second 12V output for fans or other system functions. The MPB150
is rated for convection as well as forced-air cooling. Full output power is available with as few as 15 Cubic Feet per
Minute (CFM) forced-air cooling.
The MPB150 product line is approved to the latest international regulatory standards, and displays the CE Mark.
Model Selection
MODEL
MPB150-2012G
(NOTE 2, 3, 4)
MPB150-2024G
(NOTE 2, 3, 4)
MPB150-2048G
(NOTE 2, 3, 4)
OUTPUT
VOLTAGE
(VOLTS)
+12V
12V
+24V
12V
+48V
12V
MAXIMUM OUTPUT
CURRENT (AMPS),
130 LFM
12.5A
0.5A
6.0A
0.5A
3.1A
0.5A
TOTAL
REGULATION
%
±3%
±5%
±3%
±5%
±3%
±5%
RIPPLE & NOISE
% pk-pk
(NOTE 1)
1%
1%
1%
1%
1%
1%
NOTES: 1) Maximum peak-to-peak noise expressed as a percentage of output voltage, 20 MHz bandwidth.
2) Maximum forced-air output power is 150 watts with 15 CFM airflow.
3) Maximum convection output power is 70 watts.
4) V2 is isolated from V1 and can be used as a negative or positive output.
REGULATION RANGE
11.64V to 12.36V
11.40V to 12.60V
23.28V to 24.72V
11.40V to 12.60V
46.56V to 49.44V
11.40V to 12.60V
MCD10078 Rev. 1.0, 28-Aug-08
Page 1 of 4