Monolithic Power Systems
Pin Descriptions
NC 1
NC 2
IN 3
SW 4
PGND 5
SGND 6
FAULT 7
14 SGND
13 EN
12 BP
11 NC
10 COMP
9 FB
8 SS
MP1527
2A, 1.3MHz
Step-Up Converter
COMP 1
NC 2
BP 3
EN 4
Top
View
12 PGND
11 PGND
10 SW
9 SW
Table 1: Pin Description
QFN
Pin
1
2, 6, 7
TSSOP
Pin
10
1, 2, 11
Name Function
COMP
NC
Compensation Node. COMP is the output of the internal transconductance error
amplifier. Connect a series RC network from COMP to SGND to compensate the
regulator control loop.
No Connect
3
4
5, 13
8
9, 10
11, 12
14
15
16
12
13
6, 14
3
4
5
7
8
9
BP
Output of the internal 2.4V low dropout regulator. Connect a 10nF bypass
capacitor between BP and SGND. Do not apply an external load to BP.
EN
Regulator On/Off Control Input. A logic high input (VEN>1.5V) turns on the
regulator, a logic low puts the MP1527 into low current shutdown mode.
SGND Signal Ground
IN
SW
PGND
Input Supply
Output Switching Node. SW is the drain of the internal n-channel MOSFET.
Connect the inductor and rectifier to SW to complete the step-up converter.
Power Ground
FAULT
SS
FB
Fault Input/Output. FAULT is an Input/Output that indicates that the MP1527
detected a fault and shuts the regulator off once a fault is indicated. Connect the
FAULT input/outputs together for all MP1527 regulators to force all regulators off
when any one regulator detects a fault. Once a fault is detected, cycle EN or the
input power to restart the regulator. Pull FAULT to the input voltage through a
100kresistor. Up to 20 FAULT input/outputs can be connected in parallel.
Soft-Start Input. Connect a 10nF to 22nF capacitor from SS to SGND to set the
soft-start and fault timer periods. SS sources 2µA to an external soft-start
capacitor during start-up and when a fault is detected. As the voltage at SS
increases to 1.2V, the voltage at COMP is clamped to 0.7V above the voltage at
SS limiting the startup current. Under a fault condition, SS ramps at the same rate
as in soft-start. When the voltage at SS reaches 1.2V, FAULT is asserted and the
regulator is disabled. The external capacitor at SS is discharged to ground when
not in use or when under voltage lockout or thermal shutdown occurs.
Regulation Feedback Input. Connect to external resistive voltage divider from the
output voltage to FB to set output voltage.
MP1527 Rev 1.8_8/31/05
Monolithic Power Systems, Inc.
3