DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

MLX90277 Просмотр технического описания (PDF) - Melexis Microelectronic Systems

Номер в каталоге
Компоненты Описание
производитель
MLX90277
Melexis
Melexis Microelectronic Systems  Melexis
MLX90277 Datasheet PDF : 21 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
MLX90277
Dual Programmable Linear Hall Effect Sensor
Note: All specifications apply to IC_A and IC_B unless otherwise noted.
3 Glossary of Terms
mT (milli-Tesla) = Unit of measurement for magnetic flux density. 1mT is equal to 10 Gauss.
VOQ (Output Quiescent Voltage) = Output voltage at zero magnetic field, VOUT for B = 0 mT.
Sensitivity = Change in output voltage versus change in magnetic field, VOUT / B.
TempCo (Sensitivity Temperature Compensation) = Change in Sensitivity over temperature. Listed
in units of ppm / °C (100ppm / °C. = 0.01 % / °C.).
PTC (Programming Through the Connector) = Melexis in circuit programming protocol.
MSB = Most Significant Bit.
LSB = Least Significant Bit.
4 Maximum Ratings
Parameter
Maximum Supply Voltage, VDD_MAX (Over
Voltage)
Maximum Supply Current, IDD_MAX
(Over Voltage)
Reverse Voltage, VDD_REV
Reverse Supply Current, IDD_REV
Positive Output Voltage, VOUT_MAX
Positive Output Current, IOUT_POS_FAULT
Reverse Output Voltage, VOUT_REV
Reverse Output Current, IOUT_REV_FAULT
Operating Ambient Temperature Range, TA
Storage Temperature Range, TS
Magnetic Flux Density
Table 2: Absolute Maximum Ratings
Units
30 V
50 mA
- 15 V
- 85 mA
24 V
40 mA
- 0.7 V
-50 mA
-40°C to 150°C
-55°C to 165°C
Infinite
Note: Exceeding the absolute maximum ratings may cause permanent damage. Exposure to absolute-
maximum-rated conditions for extended periods may affect device reliability.
3901090277
Rev 004
Page 3 of 21