MIW3100 Series
Test Configurations
Overcurrent Protection
Input Reflected-Ripple Current Test Setup
Input reflected-ripple current is measured with a inductor
Lin (4.7uH) and Cin (220uF, ESR < 1.0[ at 100 KHz) to
simulate source impedance.
Capacitor Cin, offsets possible battery impedance.
Current ripple is measured at the input terminals of the
module, measurement bandwidth is 0-500 KHz.
To provide protection in a fault (output overload) condition,
the unit is equipped with internal current limiting circuitry and
can endure current limiting for an unlimited duration. At the
point of current-limit inception, the unit shifts from voltage
control to current control. The unit operates normally once the
output current is brought back into its specified range.
Input Source Impedance
To Oscilloscope
+Vin +Out
+
Battery
+ Lin
Cin
Current
Probe
DC / DC
Converter
-Vin -Out
Load
Peak-to-Peak Output Noise Measurement Test
Use a Cout 0.47uF ceramic capacitor.
Scope measurement should be made by using a BNC
socket, measurement bandwidth is 0-20 MHz. Position the
load between 50 mm and 75 mm from the DC/DC Converter.
+Vin
+Out
Single Output
DC / DC
Converter
-Vin
-Out
Copper Strip
Cout
Scope
Resistive
Load
The power module should be connected to a low
ac-impedance input source. Highly inductive source
impedances can affect the stability of the power module.
In applications where power is supplied over long lines and
output loading is high, it may be necessary to use a capacitor
at the input to ensure startup.
Capacitor mounted close to the power module helps
ensure stability of the unit, it is recommended to use a good
quality low Equivalent Series Resistance (ESR < 1.0[at 100
KHz) capacitor of a 3.3uF for the 12V input devices and a
2.2uF for the 24V devices.
+
DC Power
Source
-
+Vin
+
DC / DC
Converter
Cin
-Vin
+Out
-Out
Load
Output Ripple Reduction
+Vin
+Out
Dual Output
DC / DC Com.
Converter
-Vin
-Out
Copper Strip
Cout
Cout
Scope
Resistive
Load
Scope
Design & Feature Considerations
Maximum Capacitive Load
A good quality low ESR capacitor placed as close as
practicable across the load will give the best ripple and noise
performance.
To reduce output ripple, it is recommended to use 3.3uF
capacitors at the output.
+
DC Power
Source
-
+Vin
+Out
Single Output
DC / DC
Converter
-Vin
-Out
Cout
Load
MIW3100 series have limitation of maximum connected
capacitance at the output.
+
+Vin
+Out
The power module may be operated in current limiting
mode during start-up, affecting the ramp-up and the startup
time.
DC Power
Source
Dual Output
DC / DC Com.
Converter
Cout
For optimum performance we recommend 1000uF
maximum capacitive load for dual outputs and 6800uF
-
-Vin
-Out
Load
capacitive load for single outputs.
The maximum capacitance can be found in the data sheet.