IN91260C
Operation Procedures
Symbol Definitions:
a. DP : Pulse digit, 1, 2, 3, 4, 5, 6, 7, 8, 9, 0
b. Dt : tone digit, 1, 2, 3, 4, 5, 6, 7, 8, 9, 0, *, #
c. LOCi : i = 1, 2, 3, 4, 5, 6, 7, 8, 9, 0
d. ZiZiZi : Conversation mode
e. 0 - 0 : OFF-HOOK
f. 0 - 0 : ON-HOOK
g.
: Input Level from Low to High
h.
: Input Level from High to Low
Recommended dialing, redialing, mixed dialing
and storing operations:
1. Normal dialing in pulse mode
0 - 0 , DP . . . DP, ZiZiZi 0 - 0
2. Normal dialing in tone mode
0 - 0 , Dt . . . Dt, ZiZiZi 0 - 0
3. Mixed dialing in pulse-to-tone mode
0 - 0 , DP . . . DP, MODE SELECT
, Dt . . . Dt, ZiZiZi 0 - 0
4. Redialing
0 - 0 , DP . . . DP 0 - 0 , 0 - 0 , R, ZiZiZi, 0
-0
0 - 0 , Dt . . . Dt 0 - 0 , 0 - 0 , R, ZiZiZi, 0
-0
5. Storing Numbers to Repertory Memory
(i) Off-hook Store 0 - 0 , S , DP . . . DP
or Dt . . . Dt , A/L , LOCi, 0 - 0
(ii) On/Off-hook store: 0 - 0 , S , DP . . . DP or
Dt . . . Dt , A/L , LOCi
6. Dialing from Repertory Memory
0 - 0 , A/L , LOCi, ZiZiZi 0 - 0
Functional Description
1. N-Channel Open Drain Output - DP, XMUTE
Figure 1.
2. DTMF Generator
The digitally synthesized sinewave of the
IN91260 series is well designed, with a 6 level,
12 segment, 1/2 VCC reference voltage. The THD
(Total Harmonic Distortion) of the DTMF output
is typically 1%, when VCC = 2.5 V to 5.5 V and
frequency is in the 500 HZ to 3400 HZ band.
MAXIMUM RATINGS*
Symbol
Parameter
Value
Unit
VCC
VIN
VOUT
VOUT
ITONE
PD
Tstg
DC Supply Voltage (Referenced to GND)
DC Input Voltage (Referenced to GND)
DC Output Voltage (Referenced to GND)
DC Output Voltage (DP, XMUTE)
DC Output Current(Tone)
Power Dissipation in Still Air,
Plastic DIP**
Storage Temperature
-0.3 to +6.0
V
-0.3 to VCC +0.3
V
-0.3 to VCC +0.3
V
-0.3 to 1.2
V
50
mA
500
mW
-40 to +125
°C
* Maximum Ratings are those values beyond which damage to the device may occur.
Functional operation should be restricted to the Recommended Operating Conditions.
** Durating: -10 mW/°C from 65°C to 70°C.