MB3788
s ABSOLUTE MAXIMUM RATINGS
Parameter
Supply voltage
Control input voltage
Allowable loss
Operating ambient temperature
Storage temprature
Symbol
VCC
VICTL
PD
TOP
Tstg
Conditions
—
—
Ta ≤ +25°C
—
—
* Value obtained when mounted on 4 cm × 4 cm double-sided epoxy substrate
s RECOMMENDED OPERATING CONDITIONS
Parameter
Supply voltage
Reference voltage output curren
Error amplifier input voltage
Error amplifier input voltage
Control input voltage
Output current
Operating frequency
Operating ambient temperature
Symbol Conditions
VCC
—
IOR
—
VI
—
VI
—
VICTL
—
IO
—
fosc
—
Top
—
Min.
3.6
-1
-0.2
-0.2
-0.2
3.0
100
-30
Ratings
20
20
500*
-30 to +85
-55 to +125
(TA = +25°C)
Unit
V
V
mW
°C
°C
Values
Typical
6.0
—
—
—
—
—
300
25
(TA = +25°C)
Unit
Max.
18
V
0
mA
VCC - 1.8
V
VCC
V
18
V
30
mA
1000
kHz
85
°C
7