DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

MAX8606 Просмотр технического описания (PDF) - Maxim Integrated

Номер в каталоге
Компоненты Описание
производитель
MAX8606 Datasheet PDF : 14 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
USB/AC Adapter, Li+ Linear Battery Charger
with Integrated 50mΩ Battery Switch in TDFN
NOT READY
VIN < 4V OR
VIN > 5.8V OR
VIN < VBAT
ANY STATE
POK = Hi-Z, CHG = Hi-Z,
IIN = 0mA
4V < VIN < 5.8V AND
VIN > VBAT AND
EN1 OR EN2 = 0
SET TIMER = 0
4V < VIN < 5.8V AND
VIN > VBAT AND
EN1 = EN2 = 1
EN1 OR EN2 = 0
SET TIMER = 0
SUSPEND
POK = 0, CHG = Hi-Z,
PREQUAL
IIN < 40μA
POK = 0V, CHG = 0,
IBAT = 100mA
IIN ILIM
TIMER > 30MIN AND TMR = 0
VBAT < 2.9V
SET TIMER = 0
VBAT > 3V
SET TIMER = 0
FAST-CHARGE
POK = 0, CHG = 0,
VIN(MAX) = 4.2V,
IIN(MAX) = ILIM
FAULT
POK = 0, CHG = BLINK,
IBAT = 0A
TIMER > 8 HOURS AND TMR = 0
(TIMER SUSPENDED IN 100mA MODE)
ANY CHARGING STATE
RTHM > 3.93kΩ AND
RTHM < 28.3kΩ
305Ω < RTHM < 3.93kΩ OR
RTHM > 28.3kΩ
ITOTAL < 50mA
AND VBAT = 4.2V,
SET TIMER = 0
TOP-OFF
POK = 0, CHG = Hi-Z,
VIN(MAX) = 4.2V,
IIN(MAX) = ILIM
VBAT < 4.06V
TEMPERATURE SUSPEND
IBAT = 0A
POK = PREVIOUS STATE
CHG = PREVIOUS STATE
TIMER STOPPED
TIMER > 30min
AND TMR = 0
DONE
POK = 0, CHG = Hi-Z,
IIN = 0A
ILIM = 100mA,
500mA, OR UP TO 1A
Figure 1. MAX8606 State Diagram
suspended and the CHG flag turns on and off at 2Hz.
Either the input power must be cycled or the suspend
mode enabled to clear the fault.
EN1 and EN2 Inputs
EN1 and EN2 are logic inputs that enable the charger
and select the charging current (see Table 1). Drive
EN1 and EN2 high to place the IC in suspend mode.
_______________________________________________________________________________________ 7