Mitsubishi Integrated Circuit <Digital/Analog Interface>
M62256FP
Single chip battery charger control IC
FUNCTION DESCRIPTION
1. Charging Operation
(1) Detection of Battery
When the Batt SW terminal shows "L", it indicates that the battery is installed
(2) Conditions for Quick Charge
As soon as the battery is installed, its voltage and temperature are detected. If the battey
voltage is below 5V, the preliminary charging mode starts. When the battery voltage exceeds
5V, the quick charge commences.
On the other hand, if the battery voltage exceeds 5V, the following will take place. If the
battery temperature is less than 55˚C, the quick charge will take place. If it is higher than 55˚C,
the preliminary charge mode will continue until the temperture falls below 55˚C. The charge
current used for the quick charge is set by Iset1.
(3) Initialization timer
The initialization timer is set according to Table1. The -V is not detected fot 3 minutes.
Detection of -V within the initialization timer is set to 1V to prevent erroneous detection of
-V during the initial charging.
Table1 Setting up the initialization timer
The initial battery voltage
Time of initializaton timer
Less than 5V
More than 5V but less than 6.5V
6.5V or more
20min.
5min.
3min.
(4) Charge control
When the initialization timer completes its function, detection of -V is set to 100mV and
the peak voltage of the battery held inside is compared against the battery voltage detected.
After -V is detected, the trickle charge starts at the current set by Iset2.
(5) Safety Timer
The Safety Timer controls the charging time. The quick charging time stops 3 hours and the
trickle charging time ends after 24 hours.
(6) Protective functions
(a) Over-voltage detection ………… Charging stops when the battery voltage goes to 9.5V
or higher.
(b) Over-heat detection ………… Charging stops when the battery temperature becomes
63˚C or higher. When the temperature goes to 45˚C or
lower, It recharges once.
(c) Power supply voltage detection When the power supply voltage goes below 2.8V, the
initial eset takes place.
(d) Unplugged power supply cord … When the unplugged power supply cord is detected, the
output SW is turned off.
(7) Appliciable batteries
Ni-Cd battery, Ni-MH(nickel-metalhydrogen) battery (T/t, V taper can not be detected.)