DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

L9214G Просмотр технического описания (PDF) - Agere -> LSI Corporation

Номер в каталоге
Компоненты Описание
производитель
L9214G
Agere
Agere -> LSI Corporation Agere
L9214G Datasheet PDF : 46 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
L9214A/G
Low-Cost Ringing SLIC
Preliminary Data Sheet
October 2001
Features
s Onboard balanced trapezoidal ringing generation,
40 Vrms, 1.2 crest factor:
3 REN ring load (2330 + 24 µF), 600 loop
2 REN ring load (3500 + 16 µF), 1000 loop
2 REN ring load (3500 + 1.8 µF), 500 loop
No ring relay
No bulk ring generator required
15 Hz to 70 Hz ring frequency supported
s Power supplies requirements:
VCC talk battery and ringing battery required
No 5 V supply required
No high-voltage positive supply required
s Flexible Vcc options:
3.3 V or 5 V VCC operation
3.3 V or 5 V VCC interchangeable and transparent
to users
s Power control options:
Automatic battery switch
Power control resistor
s Minimal external components required
s Ten operating states:
Forward active, fast polarity reversal
Reverse active, fast polarity reversal
Forward active, slow polarity reversal
Reverse active, slow polarity reversal
Scan
Disconnect
Ringing, line forward with high slope
Ringing, line reverse with high slope
Ringing, line forward with low slope
Ringing, line reverse with low slope
s Unlatched parallel data control interface
s Low SLIC power:
Scan 24 mW (VCC = 5.0 V)
Forward/reverse active 148 mW (VCC = 5.0 V)
Scan 17 mW (VCC = 3.3 V)
Forward/reverse on-hook 135 mW (VCC = 3.3 V)
s Supervision:
Loop start, fixed threshold with hysteresis
Ring trip filtering, fixed threshold not a function of
battery voltage, user adjustable with an external
resistor
Common-mode current for ground key applica-
tions, user-adjustable threshold
s Adjustable current limit:
10 mA to 45 mA programming range at 5 V Vcc
10 mA to 35 mA programming range at 3.3 V Vcc
s Overhead voltage:
Automatically adjusted in active mode
Clamped <56.5 V in scan and on-hook modes
s Thermal shutdown protection with hysteresis
s Longitudinal balance:
ETSI/ITU-T balance
GR-909
s Meter pulse compatible
s ac interface:
Two SLIC gain options to minimize external com-
ponents required for interface to first- or third-gen-
eration codecs
Sufficient dynamic range for direct coupling to
codec output
s 28-pin SOG, 32-pin PLCC, and 48-pin MLCC pack-
age options
s 90 V CBIC-S technology
Description
The L9214 is designed to provide battery feed, ringing,
and supervision functions on short and medium plain
old telephone service (POTS) loops. Supported round-
trip loop length is up to 1000 of wiring resistance plus
handset or ringing load. This device is designed to min-
imize power in all operating states.
The L9214 offers eight operating states. The device
assumes use of a lower-voltage talk battery, a higher-
voltage ringing battery and a single VCC supply.
The L9214 requires only a positive VCC supply. No
5 V supply is needed. The L9214 can operate with a
VCC of either 5.0 V or 3.3 V, allowing for greater user
flexibility. The choice of VCC voltage is transparent to
the user; the device will function with either supply volt-
age connected.
Two batteries may be used:
1. A high-voltage ring battery (VBAT1). VBAT1 is a maxi-
mum 70 V and is used for power ringing, scan, and
on-hook transmission modes. This supply is current
limited to the maximum power ringing current of
approximately 90 mApeak.
2. A lower-voltage talk battery (VBAT2). VBAT2 is nor-
mally used for active mode powering.
Alternatively, operation may be from a single high-volt-
age battery supply with a power control resistor to
reduce the power dissipation in the SLIC.
4
Agere Systems Inc.

Share Link: 