DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

LS4699-7E Просмотр технического описания (PDF) - Power-One Inc.

Номер в каталоге
Компоненты Описание
производитель
LS4699-7E
Power-One
Power-One Inc. Power-One
LS4699-7E Datasheet PDF : 27 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
Cassette Style
100 Watt AC-DC Converters
S Series PFC
Electrical Output Data
General Conditions
TA = 25°C, unless TC is specied.
Pin 18 (i) connected to pin 14 (S/Vo1), Uo adjusted to Uo nom (option P), R input not connected.
Sense line pins 12 (S+) and 14 (S) connected to pins 4 (Vo1+) and 8 (Vo1) respectively.
Table 4a: Output data single output modules
Output
LS 4001
5.1 V
LS 4301
12.0 V
LS 4501
15.0 V
LS 4601
24.0 V
Characteristics
Conditions
min typ max min typ max min typ max min typ max Unit
Uo Output voltage
Ui nom, Io nom
5.07
5.13 11.93
12.07 14.91
15.09 23.86
24.14 V
Uop Overvoltage protection
(supressor diode)
7.6
21
26.5
43.5
Io nom
IoL
uo 5
Output current 1
Ui min...Ui max
TC min...TC max
Output current limit 2
Ui min...Ui max
Output
voltage
noise
Low frequency
Switching freq.
Total
Ui nom, Io nom
IEC/EN 61204
BW = 20 MHz
16.0
16.2
2
15
50
8.0
8.2
2
5
40
6.5
6.7
2
5
40
4.2
4.4
2
5
40
A
mVpp
DUo U
DUo I
uo d 3
td3
aUo
Static line regulation
Ui min...Ui nom,
Ui nom...Ui max,
Io nom
Static load regulation
Ui nom, Io =
(0.1...1) Io nom
Dynamic Voltage
Ui nom, Io =
load deviation
Io nom 1/2 Io nom
regulat. Recovery time IEC/EN 61204
Temperature coefficient Ui min...Ui max
of output voltage 4
0...Io nom
±5
20
±170
0.3
0.5
±12
24
±150
0.4
-1.5
±15
30
±150
0.4
-1.5
±24 mV
48
±100
0.3
ms
1.5
mV/K
1 If the output voltages are increased above Uo nom through R-input control, option P setting, remote sensing or option T, the output cur-
rents should be reduced accordingly so that Po nom is not exceeded.
2 See: Output Voltage Regulation of Single or Double Output Modules with Outputs 1 and 2 Connected in Series.
3 See: Typical dynamic load regulation of Uo1 and Uo2.
4 Negative temperature coefcient (0...3 mV/cell and K) available on request.
5 Measured according to IEC/EN 61204 sub clause 3.10 with a probe acc. to annex A of the same standards. (See:Technical Informa-
tion: Measuring and Testing)
Edition 01/01.2001
6/27

Share Link: 