DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

12H1601-2R Просмотр технического описания (PDF) - Power-One Inc.

Номер в каталоге
Компоненты Описание
производитель
12H1601-2R
Power-One
Power-One Inc. Power-One
12H1601-2R Datasheet PDF : 4 Pages
1 2 3 4
H Series
50 Watt DC-DC Converters
EMC
Electrostatic discharge
Electromagnetic field
Electr. fast transients/bursts
Surge
Electromagnetic emissions
IEC/EN 61000-4-2, contact discharge, level 2 (4 kV) criterion A
IEC/EN 61000-4-3, level x (20 V/m)
criterion A
IEC/EN 61000-4-4, input, level 1 (0.5 kV)
criterion A
IEC/EN 61000-4-5, input, level 1 (0.5 kV)
criterion A
CISPR 22/EN 55022, 12H, conducted
class A
CISPR 22/EN 55022, 12H, radiated
class B
CISPR 22/EN 55022, 24H, 48H, radiated and conducted class B
Environmental
Operating ambient temperature
Operating case temperature TC
Storage temperature
Damp heat
Vibration, sinusoidal
Shock
Bump
MTBF
Ui nom, Io nom, convection cooled
Ui nom, Io nom
non operational
IEC/EN 60068-2-3, 93%, 40°C
IEC/EN 60068-2-6, 10...60/60...150 Hz
IEC/EN 60068-2-27, 11 ms
IEC/EN 60068-2-29, 16 ms
MIL-HDBK-217E, GB, 40°C, single output types
10...50 °C
10...80 °C
25...100 °C
21 days
0.15 mm/2 gn
15 gn
10 gn
384'000 h
Options
Extended temperature range
25...71°C, ambient, operating
Input and/or output undervoltage monitoring, excludes option V
Input and/or output undervoltage monitoring (VME), excludes option D
-7
D1D8
V2, V3
Accessories
Front panels 19" (Schroff/Intermas)
Mating H11 connectors with screw, solder, fast-on or press-fit terminals
Connector retention facilities and code key system for connector coding
Flexible PCB for connecting the converter via an H11 connector, if mounted on a PCB
Chassis or wall mounting plates for frontal access
Universal mounting brackets for chassis or DIN-rail mounting
Pin allocation
Pin Electrical Determination
2 Inhibit control input
5 Save Data or ACFAIL
8 Output voltage (positive)
11 Output voltage (negative)
14 Control input +
17 Control input
14 Output voltage (positive)
17 Output voltage (negative)
20 Output voltage (positive)
23 Output voltage (negative)
26 Protective earthing
29 DC input voltage
32 DC input voltage
H1000
i
D or V
Vo1+
Vo1
R
G
Vo1+
Vo1
Vi+
Vi
www.power-one.com
H2000
i
D or V
Vo2+
Vo2
Vo1+
Vo1
Vi+
Vi
H3000
i
D or V
Vo3+
Vo3
Vo2+
Vo2
Vo1+
Vo1
Vi+
Vi
2/12.2000
3

Share Link: 