DatasheetQ Logo
Electronic component search and free download site. Transistors,MosFET ,Diode,Integrated circuits

L9218A Просмотр технического описания (PDF) - Agere -> LSI Corporation

Номер в каталоге
Компоненты Описание
производитель
L9218A
Agere
Agere -> LSI Corporation Agere
L9218A Datasheet PDF : 30 Pages
1 2 3 4 5 6 7 8 9 10 Next Last
L9218A/G Low-Cost Line Interface
Data Sheet
November 2001
Electrical Characteristics
Minimum and maximum values are testing requirements in the temperature range of 25 °C to 85 °C and battery
range of –24 V to –70 V. These minimum and maximum values are guaranteed to –40 °C based on component
simulations and design verification of samples, but devices are not tested to –40 °C in production. The test circuit
shown in Figure 4 is used, unless otherwise noted. Positive currents flow into the device.
Typical values are characteristics of the device design at 25 °C based on engineering evaluations and are not part
of the test requirements. Supply values used for typical characterization are VCC = 5.0 V, VBAT = –48 V, unless oth-
erwise noted.
Table 4. Power Supply
Parameter
Power Supply—Powerup, No Loop Current:
ICC
IBAT (VBAT = –48 V)
Power Dissipation (VBAT = –48 V)
Power Supply—Scan, No Loop Current:
ICC
IBAT (VBAT = –48 V)
Power Dissipation (VBAT = –48 V)
Power Supply—Disconnect, No Loop Current:
ICC
IBAT (VBAT = –48 V)
Power Dissipation (VBAT = –48 V)
Power Supply Rejection 500 Hz to 3 kHz
(See Figure 5 and Figure 6)1:
VCC
VBAT
Thermal Protection Shutdown (Tjc)3
Thermal Resistance, Junction to Ambient (θJA)2, 3:
Natural Convection 2S2P Board
Natural Convection 2S0P Board
Wind Tunnel 100 Linear Feet per Minute (LFPM) 2S2P Board
Wind Tunnel 100 Linear Feet per Minute (LFPM) 2S0P Board
Min Typ Max Unit
4.6
5.6 mA
–2.4 –2.7 mA
138 158 mW
2.8
3.8 mA
–0.8 –1.0 mA
52
67 mW
1.6
mA
— –0.12 —
mA
14
— mW
30
40
150 165
30
43
27
36
dB
dB
°C
°C/W
°C/W
°C/W
°C/W
1. This parameter is not tested in production. It is guaranteed by design and device characterization.
2. Careful thermal design as a function of maximum battery, loop length, maximum ambient temperature package thermal resistance, airflow,
PCB board layers, and other related parameters must ensure that thermal shutdown temperature is not exceeded under normal use condi-
tions.
3. Airflow, PCB board layers, and other factors can greatly affect this parameter.
8
Agere Systems Inc.

Share Link: 