L6206
Figure 11. tDELAY versus CEN (VDD = 5V).
10
1
0.1
1
10
100
Cen [nF]
THERMAL PROTECTION
In addition to the Ovecurrent Detection, the L6206 integrates a Thermal Protection for preventing the device
destruction in case of junction over temperature. It works sensing the die temperature by means of a sensible
element integrated in the die. The device switch-off when the junction temperature reaches 165°C (typ. value)
with 15°C hysteresis (typ. value).
12/23