NXP Semiconductors
KTY83 series
Silicon temperature sensors
6. Characteristics
Table 6. Characteristics
Tamb = 25 °C; in liquid; unless otherwise specified.
Symbol Parameter
Conditions
R25
sensor resistance
Isen(cont) = 1 mA
KTY83/110
KTY83/120
KTY83/121
KTY83/122
KTY83/150
KTY83/151
TC
temperature coefficient
R100/R25
R−55/R25
∆R25
τth
resistance ratio
resistance ratio
drift of sensor resistance at
25 °C
thermal time constant
Tamb = 100 °C and 25 °C
Tamb = −55 °C and 25 °C
10000 h continuous
operation; Tamb = 175 °C
in still air
in still liquid
in flowing liquid
Min
990
980
980
1 000
950
950
-
1.65
0.49
-
[1] -
[1] -
[1] -
Typ
-
-
-
-
-
-
0.76
1.67
0.50
1
20
1
0.5
Max
Unit
1 010
Ω
1 020
Ω
1 000
Ω
1 020
Ω
1 050
Ω
1 000
Ω
-
%/K
1.69
0.51
-
Ω
-
s
-
s
-
s
[1] The thermal time constant is the time taken for the sensor to reach 63.2 % of the total temperature difference. For example, if a sensor
with a temperature of 25 °C is moved to an environment with an ambient temperature of 100 °C, the time for the sensor to reach a
temperature of 72.4 °C is the thermal time constant.
KTY83_SER_6
Product data sheet
Rev. 06 — 4 April 2008
© NXP B.V. 2008. All rights reserved.