Philips Semiconductors
VPS dataline processor
Preliminary specification
SAA4700
handbook, full pagewidth
CVBS
4.7 nF
2
470 pF
CSO
0.1
µF
5
6
SYNC
SEPARATOR
SAA4700
line 16
1 nF 1
DATA
data
SLICER
4.7
k
(test line 16)
11
FIELD SELECTOR
LINE 16 DECODER
INPUT
CONTROLLER
DAV
12
OUTPUT
CONTROLLER
AD = LOW
7
I2C-BUS
CONTROL
8 SCL
9
SDA
5
8
40-BIT DATA
REGISTER
data
4
40-BIT
DATA LATCH
CLOCK
REGENERATOR
75 k
(2%) 13
to VP
PLL WITH
VCS
4.7 nF
5 MHz VCO AND
17 PHASE DETECTOR
22
nF
14
6
MULTIPLEXER
TIME BASE
18 n.c.
REFERENCE
VOLTAGES
POWER-ON RESET
external
reset
34
15 16
10
8.2 k
clock pulse
Fig.1 Block diagram and test circuit.
0.1 µF
+5 V
VP
MEH095
FUNCTIONAL DESCRIPTION
Dataline 16
The information in dataline 16
consists of fifteen 8-bit words; the
total information content is shown in
Table 1; and the organization of
transmitted bytes is shown in Table 2.
Out of the fifteen possible 8-bit words
the SAA4700 extracts words 5 and 11
to 14. The contents of these words
can be read via the built-in I2C-bus
interface. The circuit is fully
transparent, thus each bit is
transferred without modification with
only the sequence of words being
changed. Words 11 to 14
are transmitted first followed by
word 5.
By evaluating the sliced sync signal
the circuit can identify the beginning
of dataline 16 in the first field. The
dataline decoder stage releases the
start code detector. When a correct
start code is detected (for timing of
start code detection see Fig.3) words
5 and 11 to 14 are decoded, checked
for biphase errors and stored in a
register bank. If no biphase error has
occurred, the contents of the register
bank are transferred to a second
register bank by the data valid control
signal. If the system has been
addressed, this transfer will be
delayed until the next start or stop
condition of the I2C-bus has been
received.
The last bit of correct information on
the dataline remains available until it
is read via the I2C-bus. Once the
stored information has been read it is
considered to be no longer valid and
the internal new data flag is reset.
Subsequently, if the circuit is
addressed, the only VPS data that will
be sent back is ”FFF to F”. The same
conditions apply after power-up when
no data can be read out. New data is
available after reception of another
error-free dataline 16.