IR21571(S)
Recommended Operating Conditions
For proper operation the device should be used within the recommended conditions.
Symbol
VBS
VS
VCC
ICC
VDC
CT
RDT
ROC
IRT
IRPH
IRUN
ISD
ICS
TJ
Definition
High side floating supply voltage
Steady state high side floating supply offset voltage
Supply voltage
Supply current
VDC lead voltage
CT lead capacitance
Deadtime resistance
Over-current (CS+) threshold programming resistance
RT lead current (Note 3)
RPH lead current (Note 3)
RUN lead current (Note 3)
Shutdown lead current
Current sense lead current
Junction temperature
Min.
VCC - 0.7
-3.0
VCCUV+
Note 2
0
220
1.0
-500
0
0
-1
-1
-40
Max.
VCLAMP
600
VCLAMP
10
VCC
50
-50
450
450
1
1
125
Units
V
mA
V
pF
k
uA
mA
oC
Electrical Characteristics
VCC = VBS = VBIAS = 14V +/- 0.25V, RT = 40.0k, CT = 470 pF, RPH and RUN leads no connection, VCPH = 0.0V,
RDT = 6.1k, ROC = 20.0kΩ, VCS = 0.5V, VSD = 0.0V, CL = 1000pF, TA = 25oC unless otherwise specified.
Supply Characteristics
Symbol Definition
VCCUV+
VUVHYS
IQCCUV
IQCCFLT
VCC supply undervoltage positive going
threshold
VCC supply undervoltage lockout hysteresis
UVLO mode quiescent current
Fault-mode quiescent current
IQCC Quiescent VCC supply current
IQCC50K VCC supply current, f= 50kHz
VCLAMP VCC zener clamp voltage
Min.
10.5
1.5
50
75
2.9
4.0
14.5
Typ.
11.4
1.8
150
200
3.8
5.5
15.6
Max.
12.4
2.2
300
300
4.3
7.0
16.5
Units
µA
mA
V
Test Conditions
VCC rising from 0V
VCC < VCCUV-
SD=5V, CS = 2V or
Tj > TSD
RT no connection, CT
connected to COM
RT =36k, RDT =
5.6k, CT=220pF
ICC = 10mA
Note 2:
Note 3:
Enough current should be supplied into the VCC lead to keep the internal 15.6V zener clamp diode on this
lead regulating its voltage.
Due to the fact that the RT input is a voltage-controlled current source, the total RT lead current is the sum of
all the parallel current sources connected to that lead. For optimum oscillator current mirror performance, this
total current should be kept between 50µA and 500µA. During the preheat mode, the total current flowing out
of the RT lead consists of the RPH lead current plus the current due to the RT resistor. During the run mode,
the total RT lead current consists of the RUN lead current plus the current due to the RT resistor.
www.irf.com
3