IK3466
Table 4 – Typical Electric Parameters of IK3466
(on default TA = 25oC, SOURCE = 0 V, unless otherwise specified)
Parameter
Symbol Mode of measurement
Typical
value
Unit
Max deviation
Current limit delay
Thermal shutdown hysteresis
tILD
ТJ = 25oC, Note 1, 2
8
kHz
150
ns
70
oC
Rise Time
Fall Time
tR
Measured in a typical
50
ns
tF
feedback IC application
50
ns
Output disable setup time
Auto-Restart ON-Time
tDST
tAR
ТJ = 25oC, Note 3
0,5
s
50
ms
Auto-Restart Duty Cycle
DCAR
5,6
%
Note
1. This parameter is derived from characterization.
2. This parameter is derived from the change in current limit measured at 1x and 4x of the di/dt shown in the
ILIMIT specification.
3. Auto-restart on time has the same temperature characteristics as the oscillator (inversely proportional to
frequency).